Programming Command Guideline
4
N9360A Multi UE Tester GSM Programming Manual
4-15
Step 8
To read the measurement results, wait until the measurement
ends.
<Send Query Command to the Tester>
*STB?
If the Response is not
0
, re send the query.
Else, proceed to the next step.
Step 9
Read the Peak TX Power test results, for example:
<Send Query Command to the Tester>
TEST:MAN:RES:TXP?
<Display Message on the PC> Peak TX Power
:<Value 3> dBm
<Display Message on the PC>
If the <Value 2> is not 0, Message is FAIL.
Else, Message is PASS.
Step 10
Start the BS Release, for example:
<Send Command to the Tester>
TEST:MAN:BSR
<Send Query Command to the Tester>
TEST:MAN:SIGN:STAT?
If the Response is not
16
, re send the query.
Else, complete the test.