5-56
N9360A Multi UE Tester GSM Programming Manual
5
Programming Command Reference
2nd Call Type
CONFigure:SEQuence:SIGNaling:CALL2:TYPE MS|BS
CONFigure:SEQuence:SIGNaling:CALL2:TYPE?
This command sets the second caller at the sixth test flow step.
The parameter is
MS
or
BS
. At preset, this is set to
BS
.
This query command returns the set of second caller with string
of
MS
or
BS
. The meaning of the return value is same as that of
the command parameter.
2nd Call Test
CONFigure:SEQuence:SIGNaling:CALL2 ON|OFF|1|0
CONFigure:SEQuence:SIGNaling:CALL2?
This command sets whether to execute the second call in a test
flow. The parameter is
ON
(1) for Run or
OFF
(0) for — (skip). At
preset, this is set to
1
.
This query command returns the set of second call test with
integer value of
1
or
0
. The meaning of the return value is same
as that of the command parameter.
2nd Release Type
CONFigure:SEQuence:SIGNaling:REL2:TYPE MS|BS
CONFigure:SEQuence:SIGNaling:REL2:TYPE?
This command sets the second caller at the sixth test flow step.
The parameter is
MS
or
BS
. At preset, this is set to
BS
.
This query command returns the set of second caller with string
of
MS
or
BS
. The meaning of the return value is same as that of
the command parameter.
Содержание GS8210
Страница 1: ...Agilent Technologies Agilent N9360A Multi UE Tester GSM Programming Manual ...
Страница 12: ...xii N9360A Multi UE Tester GSM Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 18: ...xviii N9360A Multi UE Tester GSM Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 22: ...1 4 N9360A Multi UE Tester GSM Programming Manual 1 Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 34: ...3 8 N9360A Multi UE Tester GSM Programming Manual 3 Preparing for Use THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 300: ...6 44 N9360A Multi UE Tester GSM Programming Manual 6 Programming Command Summary THIS PAGE IS INTENTIONALLY LEFT BLANK ...