CONFigure:CONDition:LIMit:ORGinoffsetspr <real
HI>
CONFigure:CONDition:LIMit:ORGinoffsetspr?
This command sets high limit for Origin Offset. The allowable
range is from
0.0
to
99.9
(%) in
0.1
steps. At preset, this is set
to
30.0
(%).
ORFS Modulation Limit
CONFigure:CONDition:LIMit:ORFS:MODulation <int>
CONFigure:CONDition:LIMit:ORFS:MODulation?
This command sets high limit for ORFS Modulation for Radio
System that is being selected. The allowable range is from
-99.9
to
0.0
(dB). At preset, this is set to
-50.0
(dB).
ORFS Switching Limit
CONFigure:CONDition:LIMit:ORFS:Switching <int>
CONFigure:CONDition:LIMit:ORFS:Switching?
This command sets high limit for ORFS Switching for Radio
System that is being selected. The allowable range is from
-99.9
to
0.0
(dBm). At preset, this is set to
-15.0
(dBm).
N O T E
This command is valid when the GSM mode is set to
EGPRS
.
N O T E
This command is valid when the GSM mode is set to
EGPRS
.
N O T E
This command is valid when the GSM mode is set to
EGPRS
.
Содержание GS8210
Страница 1: ...Agilent Technologies Agilent N9360A Multi UE Tester GSM Programming Manual ...
Страница 12: ...xii N9360A Multi UE Tester GSM Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 18: ...xviii N9360A Multi UE Tester GSM Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 22: ...1 4 N9360A Multi UE Tester GSM Programming Manual 1 Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 34: ...3 8 N9360A Multi UE Tester GSM Programming Manual 3 Preparing for Use THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 300: ...6 44 N9360A Multi UE Tester GSM Programming Manual 6 Programming Command Summary THIS PAGE IS INTENTIONALLY LEFT BLANK ...