5-190
N9360A Multi UE Tester GSM Programming Manual
5
Programming Command Reference
RFGenerator Subsystem
The RFGenerator subsystem commands are used to set and get
the controls and parameters of the Signal Generator functions.
RFGenerator Subsystem Command Reference
Radio System
RFGenerator:RFORmat <<
GSM850|GSM900|DCS1800|PCS1900
RFGenerator:RFORmat?
This command selects a Radio System to be tested. The
parameter is
GSM850
,
GSM900
,
DCS1800
or
PCS1900
. At
preset, this is set to
GSM900
.
This query command returns the selected Radio System with
strings.
RFCH
RFGenerator:CHANnel <int>
RFGenerator:CHANnel?
This command sets the channel number for each radio system
set by the
allowable range and preset values are as follows:
Table 5-49 RFCH Allowable Range and Preset Value
RFORmat
Allowable Range
Preset Value
GSM850
128 to 251
188
GSM900
0 to 124, 955 to 1023
20
DCS1800
512 to 885
698
PCS1900
512 to 810
698
Содержание GS8210
Страница 1: ...Agilent Technologies Agilent N9360A Multi UE Tester GSM Programming Manual ...
Страница 12: ...xii N9360A Multi UE Tester GSM Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 18: ...xviii N9360A Multi UE Tester GSM Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 22: ...1 4 N9360A Multi UE Tester GSM Programming Manual 1 Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 34: ...3 8 N9360A Multi UE Tester GSM Programming Manual 3 Preparing for Use THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 300: ...6 44 N9360A Multi UE Tester GSM Programming Manual 6 Programming Command Summary THIS PAGE IS INTENTIONALLY LEFT BLANK ...