96
Chapter 5
Troubleshooting
Troubleshooting Client Connections
n
You can also try
rpcinfo -t
IP_address
395180
Return
.
This
rpcinfo
command gives the response:
program 395180
version 1 ready and waiting.
If this is not working
properly, see “Troubleshooting Network Configuration”.
3
The Telnet command can be used to verify if a client has network
access to the Gateway as well. If the Telnet command returns the
message:
connection refused
, the client may not have access
(check the IP allow list configuration values) or the Gateway has run
out of resources and cannot open the Telnet session.
Client Run-time Errors
Common run-time errors that may occur on a client using an E2050
LAN/GPIB Gateway follow.
Message
Description
iopen
fails:
Invalid address errors
Use the Telnet commands to verify that the GPIB address, GPIB interface
name, and/or GPIB logical unit configuration values are correct.
iopen
fails:
No connection
The connection to the LAN/GPIB Gateway failed for one of these reasons:
n
A TCP/IP network timeout occurred because the network connection
is down or the Gateway is down.
n
The client was denied access to the Gateway because it is not in the
IP allow list. Check the IP allow list configuration values and any error
messages in a syslog file for more information.
n
The Gateway has reached its maximum concurrent client connections
and this new connection was refused. Use the Telnet
status
command
to determine the current Gateway client connection status and check the
syslog
file for error messages. You may need to have a client close its
connection or you may need to reboot the Gateway to close all client
connections to allow a new connection to be made.
iopen
fails:
Timeout
The client has timed out. The Gateway has not responded within the
appropriate timeout time because:
n
The network connection is down or the Gateway is down.
n
The server is busy performing an operation for a different client. Use
the Telnet
status
command to verify the Gateway status. You may
need to increase the Client Timeout Delta configuration value on
the LAN client.
Содержание E2050
Страница 1: ...Agilent E2050 LAN GPIB Gateway Installation and Configuration Guide ...
Страница 2: ......
Страница 10: ...10 ...
Страница 11: ...11 1 Introduction ...
Страница 23: ...23 2 Installation ...
Страница 32: ...32 Chapter 2 Installation Installing the Hardware Notes ...
Страница 33: ...33 3 Configuration ...
Страница 63: ...63 4 Administration ...
Страница 80: ...80 Chapter 4 Administration Configuring the Gateway Notes ...
Страница 81: ...81 5 Troubleshooting ...
Страница 99: ...99 A Specifications ...
Страница 102: ...102 Specifications Specifications Notes ...
Страница 103: ...103 Glossary ...
Страница 111: ...Part Number E2050 90003 Printed in U S A E0701 E2050 90003 ...