Introduction to Programming - 6
65
SCPI Data Formats
All data programmed to or returned from the dc source is ASCII. The data may be numerical or character
string.
Numerical Data Formats
Symbol Response
Formats
<NR1>
Digits with an implied decimal point assumed at the right of the least-significant digit.
Examples:
273
<NR2>
Digits with an explicit decimal point. Example:
.0273
<NR3>
Digits with an explicit decimal point and an exponent. Example:
2.73E+2
Parameter
Formats
<Nrf>
Extended format that includes
<NR1>, <NR2> and <NR3>.
Examples:
273 273. 2.73E2
<Nrf+>
Expanded decimal format that includes
<NRf>
and
MIN MAX
. Examples:
273 273.
2.73E2 MAX. MIN
and
MAX
are the minimum and maximum limit values that are
implicit in the range specification for the parameter.
<Bool>
Boolean Data. Example:
0 | 1
or
ON | OFF
Suffixes and Multipliers
Class Suffix Unit
Unit with Multiplier
Current A
ampere MA
(milliampere)
Amplitude V volt
MV
(millivolt)
Time S
second MS
(millisecond)
Common Multipliers
1E3
K
kilo
1E-3
M
milli
1E-6
U
micro
Response Data Types
Character strings returned by query statements may take either of the following forms, depending on the
length of the returned string:
<CRD>
Character Response Data. Permits the return of character strings.
<AARD>
Arbitrary ASCII Response Data. Permits the return of undelimited 7-bit ASCII. This data
type has an implied message terminator.
<SRD>
String Response Data. Returns string parameters enclosed in double quotes.