170
Chapter 10
Command Reference
:DATA
When specifying BUF3 as parameter (Comparator: OFF)
{numeric 1},{numeric 2},{numeric 3},
…
,{numeric (N
×
3)}<newline><^END>
The N sets of measurement data (a data set consists of the measurement status, measured
value, and comparator sorting result) fed into the data buffer are read out in the order of
measurement.
Where N is the number of measurement points specified with the
command
and n is an integer between 1and N:
When specifying BUF3 as parameter (Comparator: ON)
{numeric 1},{numeric 2},{numeric 3},{numeric 4},
…
,{numeric (N
×
4)}<newline><^END>
The N sets of measurement data (a data set consists of the measurement status, measured
value, and comparator sorting result) fed into the data buffer are read out in the order of
measurement.
Where N is the number of measurement points specified with the
command
and n is an integer between 1 and N:
Related commands
Equivalent key
sequence
No equivalent key can be used on the front panel.
{numeric (n
−
1)
×
3+1}
The measurement status in the n-th measurement (an integer
between 0 and 2).
{numeric (n
−
1)
×
3+2}
The measured value of the primary parameter in the n-th
measurement. If overload is detected, 9.9E37 is outputted.
{numeric (n
−
1)
×
3+3}
The measured value of the secondary parameter in the n-th
measurement. If overload is detected, 9.9E37 is outputted.
{numeric (n
−
1)
×
3+1}
The measurement status in the n-th measurement (an integer
between 0 and 2).
{numeric (n
−
1)
×
3+2}
The measured value of the primary parameter in the n-th
measurement. If overload is detected, 9.9E37 is outputted.
{numeric (n
−
1)
×
3+3}
The measured value of the secondary parameter in the n-th
measurement. If overload is detected, 9.9E37 is outputted.
{numeric (n
−
1)
×
3+4}
The comparator sorting result in the n-th measurement (an
integer between 0 and 11). The output (output value is 11) is
produced even if the comparator is off.
Содержание 4288A
Страница 18: ...16 Chapter1 Making Effective Use of This Manual How To Use This Manual ...
Страница 102: ...100 Chapter8 Avoiding Mistakes Related to Work and Daily Checks Daily Checks executing the self test ...
Страница 212: ...210 AppendixA Manual Changes Manual Changes ...
Страница 248: ...246 AppendixB Information for Replacing 4278A with 4288A Comparison of Interfaces ...
Страница 258: ...256 AppendixC Status Reporting System Using the Status Reporting System ...
Страница 282: ...280 AppendixG 4268A vs 4288A GPIB Command Correspondence Table 4268A vs 4288A GPIB Command Correspondence Table ...
Страница 288: ...286 Index Index ...