- 78 -
EZDigPro
User & Calibration Manual
LasTimOut
Laser activation time: number of tenths of a second the system
waits for a laser catch, before it automatically returns to the
previous screen. (150 is 15 seconds).
DoubleLS
Enable/Disable (ON/OFF) the second static laser catch of the
laser beam in laser enabled mode. See details in “[usage]
Laser Function.”
Filter
Depth and Reach visualized values filter.
Higher filter: more stable reading but slower response time.
DeadBaF / DeadBaM / DeadBaC
The defaults for the 3 dead bands (fine, medium, or coarse)
are listed in “Usage - Dead Band Selection” on page 74. You
can change the defaults in this Parameters screen.
LedDeUp / LedDeDw / LedReGr / LedReRe
Depth and reach indication limit of the Remote Display.
PARAMETERS
[usage]
Parameters
PARAMETERS
LasTimOut 150
DoubleLS ON
Filter 1
DeadBaF 0.010
DeadBaM 0.025
DeadBaC 0.050
LedDeUp 0.500
LedDeDw -0.100
LedReGr 0.050
LedReRe 0.100
^^^^^^^^^^^^^^^^
PARAMETERS
LasTimOut 150
DoubleLS ON
Filter 1
DeadBaF 0.010
DeadBaM 0.025
DeadBaC 0.050
LedDeUp 0.500
LedDeDw -0.100
LedReGr 0.050
LedReRe 0.100
^^^^^^^^^^^^^^^^
LedDeUp
LedDeDw
Dead Band
LedReRe
LedReGr
Caution:
Changing values in the parameters has a big effect on the performance of the system. Only access this menu area after