BuzzMode
0: the frequency of the buzzer “beep” becomes higher going close to the zero value.
1: the frequency isn’t related to the distance from zero but is different if the bucket is higher or lower to the zero. This mode
can be personalized using the following parameters:
From depth value 0 to BuzRanMin value the buzzer sound is continuous.
From depth value BuzRanMin to BuzRanMax value the buzzer sound is beeping related to the parameter
BuzFreUp.
Below zero values are complementary and the buzzer frequency is related to the BuzFreDw parameter.
GraphBarR.
Visualization limit of the depth graph bar shown in the third operator work screen.
DepthIconR
Below this value the depth icon on the left of the depth number shows that the bucket is leveled.
ReachIconR
Below this value the reach icon on the left of the reach number shows that the bucket is leveled.
[usage]
Parameters
PARAMETERS
^^^^^^^^^^^^^^^^
BuzMode 0
BuzRanMin 0.025
BuzRanMax 0.500
BuzFreMax 15
BuzFreDW 4
BuzFreUP 2
GraphBarR. 0.200
DepthIconR 0.030
ReachIconR 0.050
PARAMETERS
^^^^^^^^^^^^^^^^
BuzMode 0
BuzRanMin 0.025
BuzRanMax 0.500
BuzFreMax 15
BuzFreDW 4
BuzFreUP 2
GraphBarR. 0.200
DepthIconR 0.030
ReachIconR 0.050