- 82 -
EZDigPro
User & Calibration Manual
Although not often used, the memory function provides a way to move the excavator when you are not using a
laser as a reference (eg: moving the excavator on its tracks to dig to the same level at a different location on the site).
No Reference: Memory function is not in use.
1.) Use to move to the Memory Function (lower right quadrant of the screen will have a bold border).
2.) Then, press to enter this mode. The bold border will flash and the symbol changes to
3.) Press again to begin setting the reference point. The bold border around stops flashing.
4.) “Set Reference:” Position the bucket tip on a reference point. Choose anything stable that can also be accessed
from the next location. After moving the excavator, you will need to use this same reference point (or another
point that is at exactly the same elevation).
5.) “Keep Reference:” Press to save the value at this reference point. The bold border will flash again and the
symbol changes to
6.) Move the excavator to your next position. Place your excavator bucket tip on that same reference point used in
Step 4. Press to acquire the value.
7) The arrow is replaced by an excavator symbol. The memory function is in use (the system understands that the
elevation of the excavator has changed) and you can continue working.
To disable the Memory Function:
Press and the excavator symbol will flash; press again and the arrows icon replaces it (“No Reference”).
[usage]
Memory Function
Advanced Mode
Enter
Enter
Enter
Second location
Enter
Enter
Same reference
point, accessed from
both digging sites
First location
-