- 86 -
EZDigPro
User & Calibration Manual
Start with the bucket on the first profile point (the start point, furthest away from the cab), zeroing the depth and reach
value on the main operator working screen (figure P1 on earlier page). Select the desired profile as described previously
to reach Figure P2.
Press with the cursor over “Automatic” to enter into the profile “self learning” mode.
Press with the cursor over “Acquire P” to acquire the actual bucket position as the selected profile point.
You can now move the bucket to the next point (actual point number is shown on the same line). When the last point has
been taken, stop the acquisition by choosing “End Profile.”
The profile shape will be shown on the screen. See “Profile View” page.
ENTER A PROFILE BY COPYING EXISTING JUNCTION POINTS
[usage]
Profile Setting
Figure P3
Profile:
Use
Edit
Delete
Set the profile:
Automatic
Manual
Figure P4
Figure P5
Take a point ?
Acquire Point
End Profile
Advanced Mode
Enter
Enter
Enter
Enter