4. Power Supply
TC3
n
n
WARNING: THIS APPLIANCE MUST BE
EARTHED.
n
n
THIS APPLIANCE IS DESIGNED FOR THE
VOLTAGE STATED ON THE RATING PLATE,
WHICH IS SITUATED BEHIND THE PLINTH
COVER.
n
n
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified person to avoid a hazard.
A 1PH 32 amp 230V or 3PH 400V minimum 16A per phase
~ 50 Hz fused electrical supply is required adjacent to the
appliance. External wiring to the unit must be installed using
the mains cable provided, in accordance with the current
wiring regulations and any local regulations which apply. If
cable is shortened, new ferrules must be fitted to the stripped
conductors.
The method of connection to the mains electricity supply
must facilitate complete electrical isolation of the appliance,
by a multi-pole switch, having a contact separation of at least
3mm on all poles.
The isolator should not be positioned immediately above the
cooker, but must be fitted within 2 metres of the appliance.
The isolator maybe separate from the connection point.
The mains connection point must be accessible within the
areas shown in
Fig. 4.2
for cable routing options.
For 2 or 3 phase installations an optional adaptor kit must be
obtained (Part No. AE4M280354).
THE MAINS SUPPLY CONNECT POINT MUST BE WITHIN THE ZONES SHOWN
Fig. 4.1
Fig. 4.2
DESN 516103 A
DESN 516105
Mains cable fed from control
tray left or right exit through
ducting dependent upon
position of supply socket