9
5. Vent
Vent Pipe Connection
The appliance is shown with the oven venting from the right-
hand side
Fig. 5.1
.
To gain access remove rear panel (6 screws).
It can also be vented from theleft-hand side, by rotating the
copper elbow 180° before fitting the vent pipe.
It can also be vented from the rear using a 45° fitting and
exiting through hole in back panel.
Reseal pipe connection with aluminium tape.
When installing a AGA TC5 which is venting to the left hand
side, care must always be taken to ensure the vent pipe is
fully lagged (using insulation provided). Where the vent pipe
passes behind the hotcupboard, ensure that the mains cable
is kept away from the hot surface of the vent pipe.
Rear or right hand venting is preferable on AGA TC5
installations.
Fig. 5.1
DESN 516559
Содержание TC3G
Страница 4: ......
Страница 19: ...15 7 Circuit Diagram AGA TC3 DESN 517487...