Code
Meaning
Suggested Cause/Action
5-20
Storage impossible
because of a lack of
memory
Temporary memory shortage.
Test the SAF memory.
Replace the FCU or optional IC card.
5-21
Memory overflow
5-22
Mode table overflow after
the second page of a
scanned document
Wait for the messages which are currently in the
memory to be sent or delete some files from
memory.
5-23
Print data error when
printing a substitute rx or
confidential rx message
Test the SAF memory.
Ask the other end to resend the message.
Replace the FCU or IC memory card.
5-24
Memory overflow after the
second page of a scanned
document
Try using a lower resolution setting.
Wait for the messages which are currently in the
memory to be sent or delete some files from
memory.
5-25
SAF file access error
Replace the FCU, the IC memory card, or the
hard disk.
5-30
Mode table for the first
page to be printed was not
effective
Replace the FCU, the IC memory card, the
function upgrade card, or the hard disk.
6-00
G3 ECM - Flag detection
timer runs out while
receiving image data
Check the line connection.
Check the FCU - NCU connectors.
Replace the NCU or FCU.
Defective remote terminal.
Check for line noise or other line problems.
6-01
G3 ECM - no V.21 signal
was received
6-02
G3 ECM - EOR was
received
Try adjusting the rx cable equalizer.
Replace the FCU or NCU.
6-03
G3 ECM - non-standard
V.21 code received
The other terminal may be defective.
6-04
G3 ECM - RTC not
detected
Check the line connection.
Check connections from the NCU to the FCU.
Check for a bad line or defective remote terminal.
Replace the FCU, FCU or NCU.
6-05
G3 ECM - facsimile data
frame not received within
18 s of CFR, but there was
no line fail
Check the line connection.
Check connections from the NCU to the FCU.
Check for a bad line or defective remote terminal.
Replace the FCU, FCU or NCU.
Try adjusting the rx cable equalizer
Cross reference
Rx cable equalizer - G3 Switch 07 (PSTN), G3
Switch 08 (PABX)
6-06
G3 ECM - coding/decoding
error
Defective FCU.
The other terminal may be defective.
6-08
G3 ECM - PIP/PIN
received in reply to
PPS.NULL
The other end pressed Stop during
communication.