SERVICE CALL CONDITIONS
November 29, 1999
7-24
Symptom
Error Code
Sub-code
SC-code
Power Pack failure (Bias level error to
development roller)
9-29
58
5-58
Power Pack failure (Bias level error to
transfer roller)
9-29
59
5-59
To find out which problem has occurred, either:
•
See the Auto Service Call report that was sent to the service station by the
machine. This report lists a sub-code, as well as the error message; this sub-
code may help you find the problem.
Check the error code history using service function 03.
•
Try to clear the service call condition (for failures which are not related to the
fusing unit): switch the power off, wait 10 seconds, then switch back on.
•
An SC-code is displayed on the LCD panel when the error occurs.
To release an SC code indication relating to the fusing unit (9-22), check and
replace the fusing unit first. Then set printer switch 01 bit 0 to 1 and turn the power