![Aficio 5000L Скачать руководство пользователя страница 286](http://html1.mh-extra.com/html/aficio/5000l/5000l_service-manual_2864404286.webp)
November 29, 1999
ERROR CODES
7-29
Trouble-
shooting
Code
Meaning
Suggested Cause/Action
0-79
CI signal is detected while
waiting V21 signal
Check the connections between the FCU, NCU, &
line.
Check for line noise or other line problems.
Replace the NCU or FCU.
The remote machine may be defective.
0-80
Line was disconnected due
to timeout during line
probing.
V.34: line probing
0-81
Line was disconnected due
to timeout during equalizer
training.
V.34: equalizer training
0-82
Line was disconnected due
to timeout during control
channel start-up sequence.
V.34: phase 4
0-83
Line was disconnected due
to time out during control
channel restart sequence.
Check the line connection or line noise.
Check the connection between the NCU and the
FCU.
Increase the Tx level or adjust the cable equalizer
setting.
Use the V.17 or slower modem (with the
dedicated Tx parameter).
0-84
Line was disconnected
because error detected in
control channel start-up
sequence.
V.34: phase 4
0-85
Line was disconnected
because error detected in
control channel restart.
Check the connection between the NCU and the
FCU.
Replace the SG3 board or the FCU.
0-86
Line was disconnected
because the other terminal
requested a data rate by
MPh that was not available
in the selected symbol
rate.
The other terminal may be defective or
incompatible.
0-87
Control channel started
after unsuccessful primary
channel.
The Rx terminal restarted the control channel
because data reception in the primary channel
was not successful.
0-88
Line was disconnected
because PPR was
transmitted or received 9
times (default) times within
the same ECM frame.
Use a lower data rate at the start.
Increase the Tx level or adjust the cable equalizer
setting.
1-00
Document jam
Incorrectly inserted document or unsuitable
document type.
Check the ADF drive components and sensors.