BIT SWITCHES
November 29, 1999
4-28
System Switch 0A
No
FUNCTION
COMMENTS
0
Not used
Do not change these settings
1
Default communication mode
0: G3
1: G4
These bits determine the machine's standby
default communication mode if a G4 option has
been installed.
2
Not used
Do not change these settings.
3
Continuous polling reception
0: Disabled 1: Enabled
This feature allows a series of stations to be
polled in a continuous cycle.
4
Dialing on the ten-key pad
when the handset is off-hook
0: Disabled 1: Enabled
1: The user can dial on the ten-key pad when
the handset is off-hook.
5
On-hook dial
0: Disabled 1: Enabled
0: On-hook dial is disabled.
6
Line used for G3 transmission
0: PSTN
1: ISDN
If an ISDN kit has been installed, this bit
determines whether G3 transmissions go out
over the PSTN or the ISDN.
7
Line used when the machine
falls back from G4 to G3if the
other end is not a G4 machine
0: PSTN
1: ISDN
This bit switch has no effect if Communication
Switch 07 bit 0 is set to 0.
System Switch 0B
No
FUNCTION
COMMENTS
0
1
Automatic reset timer
Bit 1 Bit 0 Timer setting
0 0 1 minute
0 1 3 minutes
1 0 5 minutes
1 1 No limit
(1, 1): Automatic reset is disabled.
(Other): The machine returns to standby mode
when the timer expires after the last operation.
2
3
Energy Saver mode timer
Bit 3 Bit 2 Time Limit
0 0 1 minute
0 1 3 minutes
1 0 5 minutes
1 1 No limit
(1, 1): Automatic Energy Saver mode is
disabled.
(Other): The machine goes into Energy Saver
mode when the timer expires after the last
operation.
4-6
Not used
Do not change these settings.
7
Key to be pressed to exit
energy saver mode
0: Only the energy saver key
1: Any key
1: Any key can be pressed to exit energy saver
mode
System Switch 0C - Not used (do not change any of these settings)
System Switch 0D - Not used (do not change any of these settings)
System Switch 0E - Not used (do not change any of these settings)