![Aficio 5000L Скачать руководство пользователя страница 132](http://html1.mh-extra.com/html/aficio/5000l/5000l_service-manual_2864404132.webp)
BIT SWITCHES
November 29, 1999
4-24
System Switch 02
No
FUNCTION
COMMENTS
4
Automatic reset (during
communication)
0: Disabled
1: Enabled
1: Standard G3 unit - The machine automatically
returns to standby mode when a page takes
more than a certain time to send (the default
setting is 60 minutes).
This timer can be adjusted with RAM addresses
4803AC and 4803AD.
When the optional G3 or G4 unit is installed –
While the machine is in standby mode, it resets
the optional G3 or G4 unit at a certain interval
(the default setting is 15 min). This timer can be
adjusted with RAM addresses 4803AE and
4803AF.
For communication, when this timer expires
after the communication is finished, the machine
resets the optional G3 or G4 unit.
Cross reference
Service RAM Addresses, section 4.5.
5
Not used
Do not change these settings.
6
7
Memory read/write by RDS
Bit 7 6 Setting
0 0 Always disabled
0 1 User selectable
1 0 User selectable
1 1 Always enabled
(0,0): All RDS systems are always locked out.
(0,1), (1,0): Normally, RDS systems are locked
out, but the user can temporarily switch RDS on
to allow RDS operations to take place. RDS will
automatically be locked out again after a certain
time, which is stored in System Switch 03 (see
below). Note that if an RDS operation takes
place, RDS will not switch off until this time limit
has expired.
(1,1): At any time, an RDS system can access
the machine.
System Switch 03
No
FUNCTION
COMMENTS
0
to
7
Length of time that RDS is
temporarily switched on when
bits 6 and 7 of System Switch
02 are set to "User selectable"
00 - 99 hours (BCD).
This data is only valid if bits 6 and 7 of System
Switch 02 are set to "User selectable".
The default setting is 24 hours.