November 29, 1999
SERVICE RAM ADDRESSES
4-87
Service
Tables
480294 to 480296(H) - Optional equipment (Read only)
480294(H)
Bit 0: Future expander 2M/4M
Bit 1: Future expander 40M
Bit 2: Function upgrade card
Bit 3: ADF (Always “1”)
480295(H)
Bit 0: PFU is not installed
Bit 1: One PFU is installed
Bit 2: Two PFUs are installed
Bit 4: Printer unit
Bit 6: ISDN unit
480296(H)
Bit 0: FOD
Bit 2: JBIG
Bit 3: G3 interface unit
Bit 6: NIC fax kit
For the following counters, the wording in brackets indicates how these counters
appear on the system parameter list.
4802A0 to 4802A2(H) – LAN tx counter (Mail TX)
Address
High
Low
8001F6(H)
Tens digit
Unit digit
8001F7(H)
Thousands digit
Hundreds digit
8001F8(H)
Hundred thousands
digit
Ten thousands digit
8001F9(H)
Ten millions digit
Millions digit
Note: The following counters have the same data format as above.
4802A4 to 4802A6(H) – LAN rx counter (Mail RX)
4802A8 to 4802AA(H) – LAN AT counter (LAN PC-FAX)
4802AC to 4802AE(H) - TX counter (TX)
4802B0 to 4802B2(H) - RX counter (RX)
4802B4 to 4802B6(H) - Scan counter (SCN)
4802B8 to 4802BA(H) - Print counter (PRT)
4802BC to 4802BE(H) - Printer counter
4802C0 to 4802C2(H) - ADF counter (ADF)
4802C4 to 4802C6(H) - ADF PM counter
4802C8 to 4802CA(H) - ADF PM interval (Default: 30,000)
4802CC to 4802CE(H) - ADF roller counter (ADF (ROLL))
4802D0 to 4802D2(H) - ADF roller interval (Default: 30,000)
4802D4 to 4802D6(H) - MDF counter (MDF)