Soloist HPe 50/75/100
Maintenance
Table 6-4:
Control Board Fuse Information
Fuse
Description
Size
Aerotech P/N
Manufacturer's P/N
F1
Radial Lead Resettable Fuse
3 A
EIF01001
Littelfuse RGEF300
F2
Surface Mount Fuse
.05 A
EIF01028
Raychem MICROSMD005F-2
F3
Surface Mount Fuse
.05 A
EIF01028
Raychem MICROSMD005F-2
F4
Surface Mount Fuse
.05 A
EIF01028
Raychem MICROSMD005F-2
F5
Surface Mount Fuse
.05 A
EIF01028
Raychem MICROSMD005F-2
F6
Resettable Fuse
.5 A
EIF01002
Littelfuse MINISMDC050F-2
Table 6-5:
LED Description
LED
Description
ENB/FLT
Turns green to indicate that the axis is enabled. Turns red to indicate a fault condition. The
ENB/FLT LED will flash between RED and GREEN if the drive is enabled and in a fault
condition.
MARKER
Turns green to indicate that the marker input is high.
PWR*
Turns green when power is applied.
POS
Turns green to indicate that the axis is in position.
* If the power light flashes continuously and the unit does not operate, there is too much current draw from the 5V power supply or
the control supply voltage level is low.
98
Chapter 6
www.aerotech.com
Содержание Soloist HPe 100
Страница 1: ...Revision 4 09 00 Soloist HPe 50 75 100 Hardware Manual ...
Страница 14: ...Soloist HPe 50 75 100 Quick Installation Guide 14 www aerotech com This page intentionally left blank ...
Страница 24: ...Soloist HPe 50 75 100 Introduction 24 Chapter 1 www aerotech com This page intentionally left blank ...
Страница 57: ...Installation and Configuration Soloist HPe 50 75 100 Figure 2 26 PSO Interface www aerotech com Chapter 2 57 ...
Страница 94: ...94 Chapter 5 www aerotech com Soloist HPe 50 75 100 Accessories This page intentionally left blank ...
Страница 100: ...100 Chapter 6 www aerotech com Soloist HPe 50 75 100 Maintenance This page intentionally left blank ...
Страница 104: ...Soloist HPe 50 75 100 Revision History 104 Appendix B www aerotech com This page intentionally left blank ...