Installation and Configuration
Soloist HPe 50/75/100
2.2.2.1. DC Brush Motor Phasing
A properly phased motor means that the positive motor lead should be connected to the ØA motor terminal
and the negative motor lead should be connected to the ØC motor terminal. To determine if the motor is
properly phased, connect a voltmeter to the motor leads of an un-powered motor:
1. Connect the positive lead of the voltmeter to the one of the motor terminals.
2. Connect the negative lead of the voltmeter to the other motor terminal.
3. Rotate the motor clockwise by hand.
Figure 2-8:
Clockwise Motor Rotation
4. If the voltmeter indicates a negative value, swap the motor leads and rotate the motor (CW, by hand)
again. When the voltmeter indicates a positive value, the motor leads have been identified.
5. Connect the motor lead from the voltmeter to the ØA motor terminal on the Soloist HPe 50/75/100.
Connect the motor lead from the negative lead of the voltmeter to the ØC motor terminal on the Soloist
HPe 50/75/100.
N O T E :
If using standard Aerotech motors and cables, motor and encoder connection adjustments are
not required.
www.aerotech.com
Chapter 2
33
Содержание Soloist HPe 100
Страница 1: ...Revision 4 09 00 Soloist HPe 50 75 100 Hardware Manual ...
Страница 14: ...Soloist HPe 50 75 100 Quick Installation Guide 14 www aerotech com This page intentionally left blank ...
Страница 24: ...Soloist HPe 50 75 100 Introduction 24 Chapter 1 www aerotech com This page intentionally left blank ...
Страница 57: ...Installation and Configuration Soloist HPe 50 75 100 Figure 2 26 PSO Interface www aerotech com Chapter 2 57 ...
Страница 94: ...94 Chapter 5 www aerotech com Soloist HPe 50 75 100 Accessories This page intentionally left blank ...
Страница 100: ...100 Chapter 6 www aerotech com Soloist HPe 50 75 100 Maintenance This page intentionally left blank ...
Страница 104: ...Soloist HPe 50 75 100 Revision History 104 Appendix B www aerotech com This page intentionally left blank ...