2.3.2. Hall-Effect Interface (J207)
The Hall-effect switch inputs are recommended for AC brushless motor commutation but not absolutely
required. The Hall-effect inputs accept 5-24 VDC level signals. Hall states (0,0,0) or (1,1,1) are invalid and
will generate a "Hall Fault" axis fault.
Refer to
for Hall-effect device phasing.
Table 2-12:
Hall-Effect Feedback Interface Pins on the Motor Feedback Connector (J207)
Pin#
Description
In/Out/Bi
1
Chassis Frame Ground
N/A
3
+5V Power for Encoder (500 mA max)
Output
5
Hall-Effect Sensor B (brushless motors only)
Input
10
Hall-Effect Sensor A (brushless motors only)
Input
11
Hall-Effect Sensor C (brushless motors only)
Input
21
Signal Common for Encoder
N/A
Figure 2-17:
Hall-Effect Inputs (J207)
Soloist HPe 50/75/100
Installation and Configuration
Содержание Soloist HPe 100
Страница 1: ...Revision 4 09 00 Soloist HPe 50 75 100 Hardware Manual ...
Страница 14: ...Soloist HPe 50 75 100 Quick Installation Guide 14 www aerotech com This page intentionally left blank ...
Страница 24: ...Soloist HPe 50 75 100 Introduction 24 Chapter 1 www aerotech com This page intentionally left blank ...
Страница 57: ...Installation and Configuration Soloist HPe 50 75 100 Figure 2 26 PSO Interface www aerotech com Chapter 2 57 ...
Страница 94: ...94 Chapter 5 www aerotech com Soloist HPe 50 75 100 Accessories This page intentionally left blank ...
Страница 100: ...100 Chapter 6 www aerotech com Soloist HPe 50 75 100 Maintenance This page intentionally left blank ...
Страница 104: ...Soloist HPe 50 75 100 Revision History 104 Appendix B www aerotech com This page intentionally left blank ...