To provide fault tolerance from disk errors and single disk failure, the high capacity HiveManager uses level 1
RAID (Redundant Array of Independent Drives) HDDs (hard disk drives). Each HDD holds identical data, the
data that is written to one disk being mirrored to the other. The lower LEDs on the front of each HDD flash in
unison to indicate that they are writing data to memory. The upper LEDs indicate that they have power. See
.
Figure 8 Hard disk drive LEDs
If you notice that only one of the lower LEDs is flashing while the other is dark, then there is an HDD failure.
Although the HiveManager can continue with just one operational HDD, you should replace the faulty HDD
soon.
1. Turn off the HiveManager.
2. Unlock the tray door for the HDD that you want to replace.
3. Pull the tab on the left side of the door, and open the door, swivelling it on the hinge along its right side.
As you open the door, the HDD tray automatically extends.
4. Remove the failed HDD and insert a replacement
5. Close and lock the door.
6. Connect a serial cable to the console port
7. Connect one end of an RS-232 serial cable to the male DB-9 console port on the HiveManager and
other end to the serial port (or COM port) on your management system.
8. Start a serial connection by running a VT100 emulation program on your management system with the
following settings:
•
Bits per second (baud rate): 9600
•
Data bits: 8
•
Parity: none
•
Stop bits: 1
•
Flow control: none
9. Turn on the HiveManager.
10. While it is booting up, press and hold down the
CTRL+A
keys until the utility console appears.
11. From the main menu, select
Manage Arrays
. (An array is the logical representation of a physical HDD
unit.)
12. From the list of arrays, select the one that you want to rebuild.
13. Press
CTRL+R
to rebuild it.
HiveManager HDDs are not hot swappable. You must turn off the power before replacing an HDD.
The replacement disk drive must be new or, if it has been used, there must not be a root file
system on it. Also, it must be the same size as or bigger than the other disk drive.
Upper LED: Power Status
(Illuminates when the HDD
first receives power)
Lower LED: HDD Activity
(Illuminates when writing
to memory)
Hard disk drive tray
Tab
Lock
Содержание Aerohive AP141
Страница 1: ...Aerohive Hardware Reference Guide ...
Страница 7: ...Contents 6 Aerohive ...
Страница 17: ...Chapter 1 AP121 and AP141 Platforms 16 Aerohive ...
Страница 31: ...Chapter 2 The AP170 Platform 30 Aerohive ...
Страница 49: ...Chapter 4 AP330 and AP350 Platforms 48 Aerohive ...
Страница 63: ...Chapter 6 BR200 and BR200 WP Routers 62 Aerohive ...
Страница 107: ...Chapter 10 The High Capacity HiveManager 106 Aerohive ...
Страница 111: ...Index 110 Aerohive ...