Chapter 8 The AP320 Platform
90
Aerohive
If you do not pass the cables through a hole, you can run them along the wall between the wall and the
mounting plate. To create space for the cables, attach the rubber feet to the mounting plate before
attaching it to the wall. The recommended positions for the four rubber feet and the mounting instructions
are shown in
.
Figure 7 Using the rubber feet to provide clearance for cables
D
EVICE
, P
OWER
,
AND
E
NVIRONMENTAL
S
PECIFICATIONS
Understanding the range of specifications for the AP320 is necessary for optimal deployment and device
operation. The following specifications describe the physical features and hardware components, the
power adapter and PoE (Power over Ethernet) electrical requirements, and the temperature and humidity
ranges in which the device can operate.
Device Specifications
•
Chassis dimensions: 8" W x 1.5" H x 8" D (20 cm W x 3.8 cm H x 20 cm D)
•
Weight: 2 lb. (0.9 kg)
•
Antennas: Three omnidirectional 802.11b/g/n antennas, and three omnidirectional 802.11a/n antennas
•
Serial port: RJ-45 (bits per second: 9600, data bits: 8, parity: none, stop bits: 1, flow control: none)
•
Ethernet ports: two autosensing 10/100/1000 Base-T/TX Mbps ports; the ETH0 port is compliant with the
IEEE 802.3af and 802.at standards for PoE (Power over Ethernet)
Power Specifications
•
AC/DC power adapter:
•
Input:100 – 240 VAC
•
Output: 48V/0.38A
•
PoE nominal input voltages:
•
802.3af: 48 V/0.35A
•
802.3at: 48 V/0.625A
•
RJ-45 power input pins: Wires 4, 5, 7, 8 or 1, 2, 3, 6
Environmental Specifications
•
Operating temperature: 32 to 104 degrees F (0 to 40 degrees C)
•
Storage temperature: -4 to 158 degrees F (-20 to 70 degrees C)
•
Relative Humidity: Maximum 95% (noncondensing)
You can use the locking screw to secure the AP320 to the mounting plate. For information, see
"Locking the AP320" on page 89
.
Mounting plate
Attach the four rubber feet.
Run all the cables between the
mounting plate and the wall before
fastening the plate in place with the
screws. The rubber feet provide
clearance for the cables to pass.
Connect the cables to the ETH0 and
ETH1 ports and power connector.
Attach the AP to the mounting plate
.
AP
Cables
1
2
3
4
(Side view)
Rubber feet
Side of wall
Содержание Aerohive AP141
Страница 1: ...Aerohive Hardware Reference Guide ...
Страница 7: ...Contents 6 Aerohive ...
Страница 17: ...Chapter 1 AP121 and AP141 Platforms 16 Aerohive ...
Страница 31: ...Chapter 2 The AP170 Platform 30 Aerohive ...
Страница 49: ...Chapter 4 AP330 and AP350 Platforms 48 Aerohive ...
Страница 63: ...Chapter 6 BR200 and BR200 WP Routers 62 Aerohive ...
Страница 107: ...Chapter 10 The High Capacity HiveManager 106 Aerohive ...
Страница 111: ...Index 110 Aerohive ...