40
Electrical
The supplied 36-2212 harness comes with a pre-terminated AEMnet spur suitable for powering the module and
providing AEMnet/CAN connectivity. In addition, pre-terminated lengths of various color wire are supplied for
connection to sensors. The harness connector is a multi-piece assembly which has a clear plastic retainer that
must be removed prior to inserting the crimped leads into the assembly. Please see instructions later in this
manual.
Sensor Wiring
·
The Sensor Module should only be powered through the dedicated power and power ground pins,
*not*
sensor
ground
·
Every connected sensor should be connected to one of the dedicated
sensor
ground pins to ensure accurate
readings
·
Do not connect the Module's 5V sensor power to anything
other than
dedicated sensors that require 5V power,
e.g. pressure sensors
·
Route wiring away from sources of noise such as alternators, ignition components, or other high power/frequency
wiring
·
Shielded wire is suggested to reduce the susceptibility of noise; the shield should only be grounded/drained on
one end of the wiring harness
·
CAN wiring should utilized twisted pairs (> 1 TPI); shielding is recommended
·
This module is
not
compatible with K-type thermocouples
(unless a K-type amplifier is used)
; RTD-style EGT
sensors
are
compatible, e.g. AEM PN 30-2050
·
The Sensor Module's sensor ground should be at the same level as the sensor ground of any "tapped" sensors,
i.e. existing/OEM sensors that are connected to an external ECU/device
·
The device pinout section includes a Suggested Interface column. This may make integration with an
AEM Dash easier as sample layouts will be provided that follow these guidelines.
Содержание CD-5 Carbon
Страница 12: ...12 Dash Mechanical and Mounting CD 7 Mechanical ...
Страница 13: ...13 CD 5 Mechanical ...
Страница 14: ...14 CD 7F Mechanical ...
Страница 15: ...15 CD 5F Mechanical ...
Страница 16: ...16 Drill Template Drill template prints to scale ...
Страница 17: ...17 Dash Harness and Basic Wiring ...
Страница 18: ...18 Optional OBDII and Power Cable Kits ...
Страница 30: ...30 Create a new output channel using the new function Assign the new output to an item on the display ...
Страница 31: ...31 System Schematic ...
Страница 39: ...39 IMAGE NOT TO SCALE ...
Страница 41: ...41 System Schematic ...
Страница 51: ...51 CAN Transmit Rate Unit 1 50 Hz CAN Transmit Rate Unit 2 25 Hz ...
Страница 58: ...58 ID Type User Configurable 11 29 bits Termination None Ohm DLC 8 Bytes ...
Страница 64: ...64 ...
Страница 65: ...65 ...
Страница 66: ...66 ...
Страница 67: ...67 ...