16.1 - Start-up
Before starting up the boiler, the following operations must
be carried out.
16.1.1 - Instructions to the user
Instruct the user on correct use of the boiler and the whole
system in general. In particular:
Hand over the installation and use manual and all the
documentation contained in the package to the user.
Instruct the user on any special measures for discharging
burned gases, informing them that they must not be
modified.
Inform the user of the water pressure check that needs to
be done on the system and the steps required to fill it and
vent the air.
Inform the user regarding the correct temperature, control
unit/room thermostat and radiator settings for saving
energy.
16.1.2 - Filling the condensate outlet siphon
The siphon found inside the boiler must be filled with water to
create the shutter that can prevent flue gases from escaping
from pipe “5” in figures 3-3, 3-5 and 3-7.
Proceed as follows to do this:
(refer to figure 16-1)
1.- undo and remove stopper “A” shown in the figure;
2.- insert a rubber tube into hole “S” and at the other end of
the tube position a funnel;
3.- slowly pour about 5 litres of water through the funnel;
4.- reassemble everything in reverse order.
Figure 16-1 – Filling the condensate outlet siphon
WARNING! If the boiler remains off for more than
3 months, the siphon must be filled again as explained
above.
WARNING! Once the boiler is back on, check that
no exhaust gases are escaping from stopper “A”.
16.1.3 - Filling the central heating system
If the message
Err 59
appears on the display when the
boiler is powered electrically, this means that the system must
be filled. Proceed as follows:
only use clean water from the mains.
WARNING! The addition of chemical substances
such as anti-freeze must be performed in compliance with
the product instructions. In all cases, these substances
must not be introduced directly inside the boiler.
WARNING! in the case of the AGUADENS range
of hot water heaters the addition of chemical substances
such as antifreeze is strictly forbidden. Failure to observe
this rule could cause serious damage to people’s health
or even death.
1.- open the air vent valve (detail “35” in figure 3-3, 3-5, 3-7)
2.- open the filling device provided by the installer upstream
from the appliance and fill the system until the pressure
gauge reads a pressure of 1.5 bar, showing this on the
display (detail “M” in figure 17-1) (on the display the
message
Err 59
will disappear); if you want to increase
the filling pressure level you must set parameter
3022
to
the desired value (see section 20);
2.- Make sure there are no water leaks from the fittings;
3.- Reclose the filling device provided by the installer upstream
from the appliance;
4.- Bleed the heating elements;
5.- Check the pressure on the boiler display again (detail “M”
in figure 17-1). If it has dropped, fill up to 1.5 bar again (or
up to the value set).