Advantech SOM-ETX Design Guide
In additional, we also can use PAC1284 (California Micro Device) to implement both
EMI prevention and ESD protection. An practical example of using PAC1284 to
implement LPT port circuit is shown in figure 5.34.
Figure 5-32 Practical LPT Port Design
Figure 5-33 Practical Floppy Design
33 ohm
4.7k ohm
VCC
SOM-ETX
Parallel Port
STB# C55
AFD#_DENSEL C56
PD6_MOT0 C62
PD5 C68
PD4_DSKCHG# C72
PD3_RDATA# C74
PD2_WP# C76
PD1_TRK0# C78
PD0_INDEX# C80
SLCT_WGATE# C90
PE_WDATA# C88
BUSY#_MOT1 C86
ACK#_DSB# C84
SLIN#_STEP# C70
INIT#_DIR# C64
ERR#_HDSEL# C60
PD7_DSA# C58
D-Sub 25
Route to Minimum
Strobe#
Data 0
Acknowledge
Select Input
Select
Out of Paper
Busy
Data 1
Data 2
Data 3
Data 4
Data 5
Data 6
Data 7
AutoFeed#
Error#
Initial
Must be implemented in using
SOM-4481/4470/4451/4450
Must be implemented in using
SOM-4481/4475/4470/4451/4450
1k ohm
VCC
SOM-ETX
Floppy
AFD#_DENSEL C56
PD6_MOT0 C62
PD4_DSKCHG# C72
PD3_RDATA# C74
PD2_WP# C76
PD1_TRK0# C78
PD0_INDEX# C80
SLCT_WGATE# C90
PE_WDATA# C88
BUSY#_MOT1 C86
ACK#_DSB# C84
SLIN#_STEP# C70
INIT#_DIR# C64
ERR#_HDSEL# C60
PD7_DSA# C58
Route to Minimum
Index#
Write Protect#
Read Data
Track#
Diskette Change#
Motor on 0
Drive Select A#
Drive Density Select#
Head Select#
Drive Select B#
DIR#
Step#
Motor on 1
Write Data
Write Enable
Chapter 5 Carrier Board Design Guidelines
99
Содержание SOM-4450 Series
Страница 1: ...Advantech SOM ETX Series System On Modules Design Guide Version 1 0...
Страница 105: ...Advantech SOM ETX Design Guide Figure 5 39 TV DAC Signal Routing Spacing Chapter 5 Carrier Board Design Guidelines 105...
Страница 130: ...Advantech SOM ETX Design Guide 130 Chapter 8 Heat Sink Recommended Design...