51
MIC-6314 User Manual
Chapter 3
B
MC Firmware
O
peration
3.2.3
LAN
The IPMI LAN interface on MIC-6314 is achieved using a shared LAN controller with
the x86 system. In addition to the system’s PCI-Express link, a LAN controller side-
band interface (Network Controller Sideband Interface [NC-SI]) is connected to the
BMC. This NC-SI channel is used by the BMC to receive and transmit IPMI manage-
ment traffic to the network via the LAN controller.
IPMI over LAN (IOL) uses the Remote Management Control Protocol (RMCP, speci-
fied in IPMI v1.5) in the request-response pattern for IPMI communication. IPMI v1.5
LAN messages are encapsulated in RMCP packets, while the IPMI v2.0 specification
adds an enhanced protocol (RMCP+) for transferring IPMI messages and other types
of payloads. RMCP+ uses the RMCP overall packet format, but defines extensions,
such as encryption and the ability to carry additional traffic types (e.g., serial data), in
addition to IPMI messages (refer to Section 3.11 - Serial over LAN Setup).
All of the four backplane ports of MIC-6314’s Ethernet interfaces can be used for
IPMI over LAN. The RJ45 LAN connectors on the front panel cannot be used for IPMI
over LAN because no NCSI is connected.
The following IPMItool parameters are required for connecting to the BMC vial LAN:
3.3
Sensors
The MIC-6314 BMC’s main task is to monitor the board voltages and temperatures.
All important voltages and temperatures are connected to the BMC sensor.
The BMC management subsystem also monitors the following logical sensors:
BMC Watchdog sensor
FW Progress sensor
Version change sensor
Processor sensors (processor hot, thermal trip, etc.)
Advantech OEM sensor: integrity sensor
Note!
The LAN controller used for IPMI communication is connected to a cer-
tain power domain related to the front handle. Thus, the handle must be
closed to enable IPMI over LAN.
ipmitool -I lan -H <BMC IP-Address> -U <User> -P <Password>
<Command>
Command Line Syntax
-I lan
Specifies the Ethernet interface
-H <IP-Address>
IP address assigned to the BMC
-U <User>
User account, default “administrator”
-P <Password>
Password used with specified user account (default password for
administrator access is “advantech”)
Содержание MIC-6314 Series
Страница 1: ...User Manual MIC 6314 OpenVPX 6U CPU Blade with 4th 5th Gen Intel Xeon E3v4 Core Processor...
Страница 13: ...Chapter 1 1 Hardware Configuration This chapter explains how to configure the MIC 6314 hardware...
Страница 30: ...MIC 6314 User Manual 18...
Страница 31: ...Chapter 2 2 AMI APTIO BIOS Setup This chapter describes how to configure the AMI APTIO BIOS UEFI BIOS...
Страница 61: ...Chapter 3 3 BMC Firmware Operation This chapter describes the BMC firmware features...
Страница 86: ...MIC 6314 User Manual 74...
Страница 87: ...Chapter 4 4 HPM 1 Update This chapter explains how to update the software firmware components...
Страница 95: ...Appendix A A Pin Assignments This appendix describes the pin assignments...
Страница 106: ...MIC 6314 User Manual 94...
Страница 107: ...Appendix B B Programming the Watchdog Timer This appendix describes how to program the watchdog timer...
Страница 109: ...Appendix C C I O Controller List...
Страница 111: ...Appendix D D Glossary...
Страница 114: ...MIC 6314 User Manual 102...
Страница 115: ...Appendix E E BIOS Checkpoint...
Страница 122: ...MIC 6314 User Manual 110...
Страница 123: ...Appendix F F IPMI PICMG Command Subset Supported by BMC...
Страница 133: ...Appendix G G Drivers and Tools...
Страница 135: ...123 MIC 6314 User Manual Appendix G Drivers and Tools...