User Manual

EKI-8500 Series

Managed TSN Switch

Содержание EKI-8500 Series

Страница 1: ...User Manual EKI 8500 Series Managed TSN Switch ...

Страница 2: ...er installation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be bill...

Страница 3: ...and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance 1 Visit the Advantech w...

Страница 4: ... 1 x 8G 2G SFP Managed TSN Switch w Wide Temp switch 2 x Wall mounting Bracket 1 x DIN Rail mounting Bracket and Screws Warning Warnings indicate conditions which if not observed can cause personal injury Caution Cautions are included to help you avoid damaging hardware or losing data e g There is a danger of a new battery exploding if it is incorrectly installed Do not attempt to recharge force o...

Страница 5: ...our any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If one of the following situations arises get the equipment checked by service personnel 15 The power cord or plug is damaged 16 Liquid has penetrated into the equipment 17 The equipment has been exposed to moist...

Страница 6: ...te einen Brand bzw elektrischen Schlag aus lösen 13 Öffnen Sie niemals das Gerät Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden 14 Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen 15 Netzkabel oder Netzstecker sind beschädigt 16 Flüssigkeit ist in das Ge...

Страница 7: ...on period The following guidelines are also recommended Wear a grounded wrist or ankle strap and use gloves to prevent direct contact to the device before servicing the device Avoid nylon gloves or work clothes which tend to build up a charge Always disconnect the power from the device before servicing it Before plugging a cable into any port discharge the voltage stored on the cable by touching t...

Страница 8: ... Console Port 18 2 7 Power Supply Installation 19 2 7 1 Overview 19 2 7 2 Considerations 20 2 7 3 Grounding the Device 20 2 7 4 Wiring a Relay Contact 21 2 7 5 Wiring the Power Inputs 22 2 8 Reset Button 23 Chapter 3 Configuration Utility 24 3 1 First Time Setup 25 3 1 1 Overview 25 3 1 2 Introduction 25 3 1 3 Administrative Interface Access 25 3 1 4 Using the Graphical Web Interface 26 3 1 5 Conf...

Страница 9: ...on 38 4 3 3 VLANs 39 4 3 4 QoS 43 4 3 5 TSN 57 4 3 6 PTP 65 4 4 Monitor 66 4 4 1 Ports 66 4 4 2 PTP 71 4 4 3 VLANs 73 4 4 4 TSN 75 4 5 Maintenance 81 4 5 1 Restart Device 81 4 5 2 Factory Defaults 81 4 5 3 Software 81 4 5 4 Configuration 82 Chapter 5 Troubleshooting 85 5 1 Troubleshooting 86 ...

Страница 10: ...ecuring a Terminal Block to a Receptor 23 Figure 4 1 Login Screen 31 Figure 4 2 Changing a Default Password 32 Figure 4 3 Creating System Information Settings 32 Figure 4 4 Configuring IP Settings 33 Figure 4 5 Configuring IP Interfaces 33 Figure 4 6 Configuring IP Routes 34 Figure 4 7 Configuring IP Settings 35 Figure 4 8 Time Zone Configuration 36 Figure 4 9 Daylight Saving Time Configuration 36...

Страница 11: ... Figure 4 46 Interface Name to Port Number Map 71 Figure 4 47 PTP External Clock Mode 71 Figure 4 48 802 1AS Clock Instance Specific Statistics 72 Figure 4 49 VLAN Membership Status 73 Figure 4 50 VLAN Membership Status 74 Figure 4 51 TSN Egress Port Frame Preemption Status 75 Figure 4 52 TAS Status Parameters 76 Figure 4 53 PSFP Stream Parameter Status 77 Figure 4 54 PSFP Stream Filter Status 77 ...

Страница 12: ...Chapter 1 1Product Overview ...

Страница 13: ...rupted Based on IEEE 802 1CB for Seamless Redundancy Frame Replication and Elimina tion for Reliability sends duplicate copies of each frame over multiple paths which control applications that cannot tolerate packet losses 1 2 Specifications Specifications Description Interface I O Port 8 x 10 100 1000BASE T TX RJ 45 2 x SFP mini GBIC port Management Port 1 x 10 100 1000BASE T TX RJ 45 Console Por...

Страница 14: ... 1CB IEEE 802 1Qbv IEEE 802 1Qbu Time Synchroni zation IEEE 802 1AS gPTP Time Precision 1 ns IEEE 1588v2 PTP QoS Priority Queue Scheduling WRR Weighted Round Robin SP Strict Scheduling Priority Hybrid Priority Class of Service IEEE 802 1p Based CoS IP TOS DSCP based CoS Rate Limiting Ingress Rate limit Egress Rate limit Security Port Security Static Dynamic IP Source Guard ARP Spoofing Prevention ...

Страница 15: ...tion 12 1W 48VDC System Power Input 12 to 48VDC Certification Safety UL 62368 1 compliant EMI EN 55032 Class A EN 61000 6 4 FCC Part 15 Sub part B Class A EMS EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 Shock IEC 60068 2 27 Freefall IEC 60068 2 32 Vibration IEC 60068 2 6 Railway Track Side EN 50121 4 Specifications Description ...

Страница 16: ...B9 male on computer to RS232 managed switch RJ45 female 3 Management port Allows remote management and configuration of the device 4 ETH port RJ45 ports x 8 5 LNK ACT LED Link activity LED 6 Speed LED Orange 100M Green 1G 7 System LED panel See System LED Panel on page 6 for further details 8 ETH port 2 x Gigabit copper SFP combo ports 2 4 6 8 1 3 5 7 P10 P09 MGMT Console Reset PWR1 PWR2 SYS P Fai...

Страница 17: ... Powered up Off Power down or not installed 3 SYS Solid green System is operating normally Off System is powered down system crash operation initiating 4 P Fail Solid green Active when power failure is detected 5 P10 Solid green When port 10 SFP is linked at 1000 Mbps Off Not connected 6 P9 Solid green When port 9 SFP is linked at 1000 Mbps Off Not connected PWR1 PWR2 SYS P Fail P10 P09 1 2 3 5 4 ...

Страница 18: ...m Description 1 Wall mounting holes Screw holes x6 used to install wall mounting plate 2 DIN Rail mounting plate Mounting plate used to install a standard DIN rail 2 1 1 No Item Description 1 Ground terminal Screw terminal used to ground chassis 2 Terminal block Connect cabling for power and alarm wiring 1 2 ...

Страница 19: ...Chapter 2 2Switch Installation ...

Страница 20: ...t proper airflow the switch can overheat To prevent performance degredation and damage to the switch make sure there is clerance at the top and bottom and around the exhaust vents 2 1 1 Connecting Hardware In this instruction it will explain how to find a proper location for your Modbus Gate ways and how to connect to the network hock up the power cable and connect to the EKI 8500 Series 2 2 Verif...

Страница 21: ... DIN rail clip hooks over the top of the DIN rail as shown in the following illustration Make sure the DIN rail is inserted behind the spring mechanism 2 Once the DIN rail is seated correctly in the DIN rail clip press the front of the switch to rotate the switch down and into the release tab on the DIN rail clip If seated correctly the bottom of the DIN rail should be fully inserted in the releas...

Страница 22: ...n of a completed DIN installation proce dure Figure 2 2 Correctly Installed DIN Rail Kit 3 Grasp the bottom of the switch and slightly rotate it upwards If there is resis tance the switch is correctly installed Otherwise re attempt the installation pro cess from the beginning ...

Страница 23: ...tion resistance than the DIN rail vertical mount Before the device can be mounted on a wall you will need to remove the DIN rail plate 1 Rotate the device to the rear side and locate the DIN mounting plate 2 Remove the screws securing the DIN mounting plate to the rear panel of the switch 3 Remove the DIN mounting plate Store the DIN mounting plate and provided screws for later use 4 Align the wal...

Страница 24: ...to attach the wall screws x6 6 Locate the installation site and place the switch against the wall making sure it is the final installation location 7 Use the wall mount plates as a guide to mark the locations of the screw holes 8 Drill four holes over the four marked locations on the wall keeping in mind that the holes must accommodate wall sinks in addition to the screws 9 Insert the wall sinks i...

Страница 25: ... the wall mount plate on the screws and slide it forward to lock in place see the following figure Figure 2 6 Wall Mount Installation 13 Once the device is installed on the wall tighten the screws to secure the device Note Make sure the screws dimensions are suitable for use with the wall mounting plate Do not completely tighten the screws into the wall A final adjust ment may be needed before ful...

Страница 26: ...ect the Tx transmit port of device I to the Rx receive port of device II and the Rx receive port of device I to the Tx transmit port of device II If you make your own cable we suggest labeling the two sides of the same line with the same letter A to A and B to B as shown below or A1 to A2 and B1 to B2 2 4 1 Installing SFP Modules To connect the fiber transceiver and LC cable use the following guid...

Страница 27: ...cedures to install any additional SFP transceivers in the switch The fiber port is now setup 2 4 2 Removing SFP Modules To disconnect an LC connector use the following guidelines 1 Press down and hold the locking clips on the upper side of the optic cable Note If you are attaching fiber optic cables to the transceiver continue with the following step Otherwise repeat the previous steps to install ...

Страница 28: ...ter is rec ommended The connector bodies on the RJ45 Ethernet ports are metallic and con nected to the GND terminal For best performance use shielded cabling Shielded cabling may be used to provide further protection Figure 2 12 Ethernet Plug Connector Pin Position Maximum cable length 100 meters 328 ft for 10 100 1000BaseT Note Replace the dust plug on the slot if you are not installing a transce...

Страница 29: ...s RJ45 RJ45 port a wired connection for management can be established Figure 2 13 Serial Console Cable Figure 2 14 DB 9 Pin Position Figure 2 15 Pin Assignment DB9 Connector RJ45 Connector NC 1 Orange White NC 2 Orange 2 3 Green White NC 4 Blue 5 5 Blue White 3 6 Green NC 7 Brown White NC 8 Brown To terminal or PC To console port 5 9 1 6 3 6 8 1 7 2 5 4 TXD RJ45 Male RXD NC NC NC NC GND GND 2 3 7 ...

Страница 30: ... power supply unit to reduce network down time as a result of power loss Dual power inputs are supported and allow you to connect a backup power source Figure 2 16 Power Wiring for EKI 8500 Series Warning Power down and disconnect the power cord before servicing or wiring the switch Caution Do not disconnect modules or cabling unless the power is first switched off The device only supports the vol...

Страница 31: ...to the various devices for more effective manage ment and servicing 2 7 3 Grounding the Device Note Routing communications and power wiring through the same conduit may cause signal interference To avoid interference and signal degra dation route power and communications wires through separate con duits Caution Do not disconnect modules or cabling unless the power is first switched off The device ...

Страница 32: ...section details the wiring of the relay output The terminal block is wired and then installed onto the terminal receptor Figure 2 18 Terminal Receptor Relay Contact The terminal receptor includes a total of six pins two for PWR1 two for PWR2 and two for a fault circuit Caution Do not block air ventilation holes Note Before applying power to the grounded switch it is advisable to use a volt meter t...

Страница 33: ...or 2 Remove the terminal block from the switch Figure 2 20 Removing a Terminal Block 3 Insert a small flat bladed screwdriver in the V1 V1 wire clamp screws and loosen the screws 4 Insert the negative positive DC wires into the V V terminals of PW1 If setting up power redundancy connect PW2 in the same manner Caution Do not disconnect modules or cabling unless the power is first switched off The d...

Страница 34: ...inal block to secure it to the terminal block recep tor If there is no gap between the terminal block and the terminal receptor the ter minal block is seated correctly Figure 2 22 Securing a Terminal Block to a Receptor 2 8 Reset Button Reset configuration to factory default Press and hold Reset button for 5 seconds System reboot Press and hold Reset button for 2 seconds 1 A 2 4 V 1 A 2 4 V Loosen...

Страница 35: ...Chapter 3 3Configuration Utility ...

Страница 36: ...f explanation of how RSTP works is given in the Spanning Tree section The switch is capable of communicating with other SNMP capable devices on the network to exchange management information This statistical derived information from the network is saved in the Management Information Base MIB of the switch The MIB is divided into several different information storage groups These groups will be ela...

Страница 37: ...dress Here to reach the System Settings menu The settings in this menu control the switch s general net work configuration DHCP Enabled Disabled The switch can automatically obtain an IP address from a server using the Dynamic Host Configuration Protocol DHCP This can speed up initial set up as the network administrator does not have to find an open IP address IP Address and subnet mask configurat...

Страница 38: ...t cable between network interfaces The second local area network standard is 100BASE T which runs at 100Mbps over the same twisted pair Ethernet cable Lastly there is 100BASE F which enables fast Ethernet 100Mbps over fiber These options are available 10h 10 Mbps Half Duplex 10f 10 Mbps Full Duplex 100h 100 Mbps Half Duplex 100f 100 Mbps Full Duplex 1000f 1000 Mbps Full Duplex On managed switches ...

Страница 39: ...and Line Interface via Telnet Press any key to continuye and enter the user name and password as below with default the screen will displays User name admin Password admin 3 3 Web Browser Configuration The switch has an HTML based user interface embedded in the flash memory The interface offers an easy to use means to manage basic and advanced switch func tions The interface allows for local or re...

Страница 40: ...ng infor mation guides you through the logging in process 1 Launch your web browser on the PC 2 In the browser s address bar type the switch s default IP address 192 168 1 1 The login screen displays 3 Enter the user default name and password admin admin 4 Click OK on the login screen to log in The main interface displays 3 ...

Страница 41: ...Chapter 4 4Managing Switch ...

Страница 42: ...4 1 Login Screen 4 2 Recommended Practices One of the easiest things to do to help increase the security posture of the network infrastructure is to implement a policy and standard for secure management This practice is an easy way to maintain a healthy and secure network After you have performed the basic configurations on your switches the following is a recommendation which is considered best p...

Страница 43: ...scribes the items in the previous figure Item Description System Contact Enter identification information to describe the contact option for management events String length is 0 to 255 Only ASCII characters from 32 to 126 are supported System Name Enter the name to the assigned contact information using alpha numeric characters A Za z digits 0 9 and minus symbol String length is 0 to 255 No space ...

Страница 44: ...enu to set the mode as a Host or a Router In Host mode IP traffic between interfaces is not routed while in Router mode traffic is routed between all interfaces DNS Server 0 3 Click the drop down menu to set the DNS name resolution for the device The following modes are supported No DNS server default No DNS server is used Configured IPv4 or IPv6 Enter the specified IPv4 IPv6 address of the DNS Se...

Страница 45: ...seconds when trying to obtain a DHCP lease Once threshold is reached the configured IPv4 address is used as the IPv4 interface address A value of zero disables the function Current Lease An active lease is identified by the DHCP interface s current interface address as provided by the DHCP server IPv4 Address If DHCP is not enabled enter the IPv4 address to designate the interface IPv4 Mask If DHC...

Страница 46: ...t route has a mask length of 0 Gateway Enter the IP address of the IP gateway The gateway and Network must be of the same type Next Hop VLAN IPv6 Enter the IPv6 to specify the interface associated with the gateway Range 1 to 4094 The range is valid only when the corresponding IPv6 interface is valid Link local addresses must specify the next hop VLAN If the IPv6 gateway address is not link local t...

Страница 47: ... below for a defined Daylight Saving Time duration To configure the daylight saving time Figure 4 9 Daylight Saving Time Configuration Item Description Time Zone Click the drop down menu to select manual to enter a custom time zone setting or an available world wide time zone Hours For manual entries enter the number of hours offset from UTC Minutes For manual entries enter the number of minutes o...

Страница 48: ... repeats every year Non Recurring A single time configuration Start Time Settings Enter the Month Date Year Hours and Minutes to setup start time End Time Settings Enter the Month Date Year Hours and Minutes to setup end time Offset Settings Enter the number of minutes to add during Daylight Saving Time Range 1 to 1439 Save Click Save to store the settings Reset Click Reset to clear the settings I...

Страница 49: ...ent link speed of the port Configured Link Speed Click the drop down menu to select an available link speed for the given switch port Only speeds supported by the specific port are shown Disabled Disables the switch port operation Auto negotiation Port auto negotiating speed and duplex with the link partner and selects the highest speed that is compatible with the link partner 10Mbps HDX Forces th...

Страница 50: ...0 1 2 3 7 PFC is not supported through auto negotiation PFC and Flowcontrol cannot both be enabled on the same port Maximum Frame Size Enter the maximum frame size allowed for the switch port including FCS The range is 1518 10240 bytes Excessive Collision Mode Configure the port transmit collision behavior Discard Discard frame after 16 collisions default Restart Restart backoff algorithm after 16...

Страница 51: ...N Configuration Allowed Access VLANs Enter the string to indicate the allowed access VLANs VLAN 1 is enabled by default List range entry is supported Ethertype for Custom S ports Enter the string to indicate the ethertype TPID used for custom s ports The setting is in force for all ports whose Port Type is set to S Custom Port Port VLAN Configuration Port Displays the logical port number for the e...

Страница 52: ...he VLANs that a trunk port is member of may be limited by the use of Allowed VLANs Frames classified to a VLAN that the port is not a member of are discarded By default all frames but frames classified to the Port VLAN a k a Native VLAN get tagged on egress Frames classified to the Port VLAN do not get C tagged on egress Egress tagging can be changed to tag all frames in which case only tagged fra...

Страница 53: ...re dropped Ingress Filtering Click to enable default or disable ingress filtering Enabled frames classified to a VLAN that the port is not a member of get discarded Disabled frames classified to a VLAN that the port is not a member of are accepted and forwarded to the switch engine However the port will never transmit frames classified to VLANs that it is not a member of Ingress Acceptance Click t...

Страница 54: ...lick Port Classification Forbidden VLANs Enter the string to indicate the exclusion of membership to a VLAN membership Note Dynamic VLAN protocols like MVRP and GVRP must be prevented from dynamically adding ports to VLANs which is achieved through this function By default the field is left blank indicating that the port can be a member of all possible VLANs Save Click Save to create a new user ac...

Страница 55: ...PCP Click the drop down menu to select the default PCP value All frames are classified to a PCP value If the port is VLAN aware and the frame is tagged then the frame is classified to the PCP value in the tag Otherwise the frame is classified to the default PCP value DEI Click the drop down menu to select the default DEI value All frames are classified to a DEI value If the port is VLAN aware and ...

Страница 56: ...p Enter the string to indicate the ID for the Egress Map range 0 to 511 An empty field indicates no map selection Save Click Save to create a new user account Reset Click Reset to clear the settings Item Description Item Description Port Displays the port number for the entry Enable Click to enable or disable default the port policer for the port Rate Enter the string to indicate the control rate ...

Страница 57: ...QoS Egress Port Schedulers Item Description Port The port number for which the configuration below applies Enable E Enable or disable the port policer for this switch port If enabled rate and unit options display Rate Enter the string to indicate the rate for the queue policer values 10 to 13128147 for kbps 1 to 13128 Mbps fps kfps The field displays if one of the queue policers is enabled Unit Cl...

Страница 58: ... the weight for this queue and port Item Description Scheduler Mode Click the drop down menu to indicate the number of queues to be scheduled as strict and how many are scheduled as weighted on the switch port Queue Shaper Enable Click to enable or disable default the function Queue Shaper Rate Enter the string to indicate the rate for the queue policer values 10 to 13128147 for kbps 1 to 13128 Mb...

Страница 59: ...Queue Scheduler Percent Displays the queue weight as a percentage Port Shaper Enable Click to enable or disable default port shaper Port Shaper Rate Enter the string to indicate the rate for the port shaper values 100 to 13107100 kbps 1 to 13107 Mbps Port Shaper Unit Click the drop down menu to select the unit measurement values kbps Mbps Port Shaper Rate type Click the drop down menu to select th...

Страница 60: ... Port DSCP Configuration settings for all switch ports 1 Navigate to Configuration QoS and click Port DSCP Item Description Port Displays the logical port for the entry Click on the port number to to configure tag remarking Mode Shows the tag remarking mode for this port Classified Use classified PCP DEI values Default Use default PCP DEI values Mapped Use mapped versions of CoS and DPL Item Descr...

Страница 61: ...ion settings Ingress Classify Click the drop down menu to select the port classification Options Disable No Ingress DSCP Classification DSCP 0 Classify if incoming or translated if enabled DSCP is 0 Selected Classify only selected DSCP for which classification is enabled as specified in DSCP Translation window for the specific DSCP All Classify all DSCP Egress Click the drop down menu to set the e...

Страница 62: ...e to Configuration QoS and click DSCP Translation Item Description DSCP Displays the maximum number of supported DSCP 64 Trust Click to enable or disable default trust classification Only frames with trusted DSCP values are mapped to a specific CoS and DPL Frames with untrusted DSCP values are treated as a non IP frame CoS Click the drop down menu to set the CoS value values 0 to 7 DPL Click the d...

Страница 63: ...igate to Configuration QoS and click DSCP Classification Item Description DSCP Displays the maximum number of supported DSCP values range 0 to 63 Trust Click to enable or disable default trust for the DSCP entry CoS Click the drop down menu to select the precedence level values 0 to 3 DPL Click the drop down menu to select the CoS value values 0 to 7 Save Click Save to save changes Reset Click Res...

Страница 64: ...hrough the rules 1 Navigate to Configuration QoS and click Ingress Map The QoS Ingress Map Configuration page displays Figure 4 26 QoS Ingress Map Configuration The following table describes the items in the previous figure Item Description CoS Displays the identifier for the class of service entry DSCP DP0 Click the drop down menu to select the classified DSCP value values 0 to 63 for Drop Preced...

Страница 65: ... Egress Map The QoS Egress Map Configuration page displays Figure 4 27 QoS Egress Map Configuration The following table describes the items in the previous figure Key Type Displays the key type for the entry Options PCP Use PCP as key for tagged frames and none for the rest Table width 1 PCP DEI Use PCP DEI as key for tagged frames and none for the rest Table width 2 DSCP Use DSCP as key for IP fr...

Страница 66: ...se classified DSCP as key Table width 8 DSCP DPL Use classified DSCP and DPL as key Table width 32 QoS Egress Map Modification Buttons It is possible to modify each map or add new maps in the table using the following buttons Edit Edits the map Delete Deletes the map Add Adds a new map in the table Refresh Click Refresh to refresh the page Remove All Click Remove All to remove all Ingress Maps and...

Страница 67: ...f frame Possible values are Any Match any frame type Ethernet Match EtherType frames LLC Match LLC frames SNAP Match SNAP frames IPv4 Match IPv4 frames IPv6 Match IPv6 frames Action Indicates the classification action taken on ingress frame if parameters configured are matched with the frame s content Possible actions are CoS Classify Class of Service DPL Classify Drop Precedence Level DSCP Classi...

Страница 68: ...o 13128147 fps or kbps and 1 to 13128 kfps or Mbps Supported rates are divisible by 10 fps or 25 kbps Unit Click the drop down menu to select the unit of measure for the global storm policer rate value fps kfps kbps or Mbps Save Click Save to save changes Reset Click Reset to undo any changes made locally and revert to previously saved values Item Description Port Displays the port number for the ...

Страница 69: ...provides an overview of TSN Egress Port Frame Preemption Configuration 1 Navigate to Configuration TSN and click Frame Preemption The Frame Preemption Configuration page displays Figure 4 32 Frame Preemption Configuration Item Description Procedure Click the drop down menu to select how to ensure PTP state Options None Time only Time and Ptp Timeout Enter a string to indicate the maximal number of...

Страница 70: ...C Merge sublayer in the transmit direction Start without LLDP Click to enable or disable default when this field is checked Frame Preemption will be active when Frame Preemption TX is checked Verify Disable TX Click to enable or disable default the value of the 802 3br aMACMergeVerifyDisableTx parameter for the port This value determines whether the verify function is disabled TRUE or enabled FALS...

Страница 71: ...range 0 to 256 The integer value indicates the number of entries Gate Control Elements in the Gate Control List GCL Displays the link to the Gate Control List parameter configuration Cycle Time Cycle Time Value Enter the string to indicate the Admin Cycle Time range admin cycle Time 1 to 999999999 cycle time 256 to 999999999 nanoseconds as defined by the number of units defined in the Unit field T...

Страница 72: ...ic class supported by the port values unsigned integer in the range 0 to 10240 A value of 0 is interpreted as the Maximum SDU size supported by the underlying MAC 10240 The default value of the Maximum SDU parameter is 1536 The Maximum SDU size parameter is used to calculate the guard band time Maximum SDU 8 LINK_SPEED sec If frame preemption is enabled and a gate operaton is SetAndHold the guard ...

Страница 73: ...red EBB Additional information required CF Additional information required CM Additional information required Drop on Yellow Additional information required Mark RED Click to enable or disable default the FlowMeterMarkAllFramesRed parameter contains a Boolean value that indicates whether if the MarkAllFramesRed function is enabled all frames are to be discarded TRUE or not FALSE Add New Entry Clic...

Страница 74: ...tion Oversize Block Enable Click to enable or disable default the object to indicate whether the StreamBlockedDueToOversizeFrame function is enabled TRUE or disabled FALSE Add New Entry Click Add New Entry to add Stream Filter entry Save Click Save to save changes Reset Click Reset to undo any changes made locally and revert to previously saved values Item Description Item Description Delete Click...

Страница 75: ...ig Change The ConfigChange parameter signals the start of a configuration change for the gate when it is set to TRUE This should only be done when the various administrative parameters are all set to appropriate values Add New Entry Click Add New Entry to add Stream Gate entry Save Click Save to save changes Reset Click Reset to undo any changes made locally and revert to previously saved values I...

Страница 76: ...esh to refresh the page immediately Item Description Item Description One_PPS_Mode Click the drop down menu to select the One_pps_mode configuration The following values are possible Output Enable the 1 pps clock output Input Enable the 1 pps clock input Disable Disable the 1 pps clock in out put External Enable Click the drop down menu to configure the External Clock output The following values a...

Страница 77: ...dit the Clock details HW Domain Indicates the HW clock domain used by the clock Device Type Indicates the Type of the Clock Instance There are five Device Types 1 Ord Bound clock s Device Type is Ordinary Boundary Clock 2 P2p Transp clock s Device Type is Peer to Peer Transparent Clock 3 E2e Transp clock s Device Type is End to End Transparent Clock 4 Master Only clock s Device Type is Master Only...

Страница 78: ...he number of frames discarded due to ingress or egress congestion Filtered Displays the number of received frames filtered by the forwarding process Auto refresh Click to enable or disable the automatic refresh function for the page Automatic refresh occurs every 3 seconds Refresh Click Refresh to refresh the page immediately Clear Click Clear to clear the counters for all ports Item Description I...

Страница 79: ...6 frames Action Displays the classification action taken on ingress frame if parameters configured are matched with the frame s content Values CoS Classify Class of Service DPL Classify Drop Precedence Level DSCP Classify DSCP value PCP Classify PCP value DEI Classify DEI value Policy Classify ACL Policy number Ingress Map Classify Ingress Map ID Conflict Displays the conflict status of the QCL en...

Страница 80: ...ast Displays the number of received and transmitted broadcast packets Rx and Tx Pause Displays the count of the MAC Control frames received or transmitted on this port that have an opcode indicating a PAUSE operation Receive and Transmit Size Counters Displays the number of received and transmitted good and bad packets split into categories based on their respective frame sizes Receive and Transmi...

Страница 81: ...d frames filtered by the forwarding process Tx Drops Displays the number of frames dropped due to output buffer congestion Tx Late Exc Coll Displays the number of frames dropped due to excessive or late collisions Item Description Rx MM Fragments Displays the count of received MAC frame fragments Rx MM Assembly Ok Displays the count of MAC frames that were successfully reassembled and delivered to...

Страница 82: ...ides a means to convert from one to the other 1 Navigate to Monitor PTP and click PTP The PTP External Clock Mode page displays Figure 4 47 PTP External Clock Mode The following table describes the items in the PTP External Clock Mode page Item Description Interface Name Displays the name of the interface entry Port Number Displays the number identifying the port corresponding to the interface Ite...

Страница 83: ...vered clock Auto AUTO Select clock control based on PTP profile and available HW resources Clock Frequency Displays the current clock frequency values 1 to 25000000 1 25MHz PTP Clock Description Inst Displays the instance of a clock instance for the entry ClkDom Displays the clock domain for the instance entry Device Type Displays the clock instance type Ord Bound Clock s Device Type is Ordinary B...

Страница 84: ...lays the counter that increments every time a Pdelay_Resp message is transmitted PdelayResponse FollowUpCount Displays the counter that increments every time a Pdelay_Resp_Follow_Up message is transmitted AnnounceCount Displays the counter that increments every time an Announce message is transmitted Item Description Item Description Start from VLAN First Page Click the icon to display the first p...

Страница 85: ...ed by a user Values Unaware C Port S Port S Custom Port Ingress Filtering Displays if ingress filtering is enabled or disabled for the entry Frame Type Displays the acceptable frame type as configured by a user Values All Taged Untagged Port VLAN ID Displays the port VLAN ID as configured for the entry Tx Tag Displays the TX Tag requirements as configured for the entry Values Tag All Tag PVID Tag ...

Страница 86: ...he page immediately Item Description Item Description Port Displays the logical port of the entry Hold Advance Displays the value of the holdAdvance parameter for the Port in nanoseconds Release Advance Displays the value of the releaseAdvance parameter for the Port in nanoseconds Preemption Active Displays the value is active TRUE when preemption is operationally active for the Port and idle FALS...

Страница 87: ...te of the gate associated with each queue for the Port Cycle Time Value Displays the operational value of the gating cycle for the Port Cycle Time Unit Displays the operational Cycle Time unit Cycle Time Extension Displays the integer number of nanoseconds defining the maximum amount of time by which the gating cycle for the Port is permitted to be extended when a new cycle configuration is instal...

Страница 88: ...r for the Port GCL Displays the link to the GCL parameter status Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refresh Click Refresh to refresh the page immediately Item Description Item Description Max Stream Filter Instances Displays the maximum number of stream filter instances that are supported by this Bridge component Max Stream Gate I...

Страница 89: ...on Item Description Clear Click to clear the entry for the next Clear operation SFI ID Displays the maximum number of stream filter instances that are supported by this Bridge component Matching Frame Count Displays the counts received frames that match this stream filter Passing Frame Count Displays the counts received frames that pass the gate associated with this stream filter Not Passing Frame...

Страница 90: ...er in nanoseconds Base Time Displays the operational value of the BaseTime paramter The value is a representation of a PTPtime value consisting of a 48 bit integer number of seconds and a 32 bit integer number of nanoseconds Current Time Displays the current time in PTPtime as maintained by the local system Config Change Time Displays the PTPtime at which the next config change is scheduled to occ...

Страница 91: ... box to refresh the page automatically Automatic refresh occurs every 3 seconds Refresh Click Refresh to refresh the page immediately Clear All Click Clear All to clear the blocked flags for all entries Item Description Item Description Clear Click to mark an entry for clearance during the following Clear operation Instance Displays the FRER instance ID Mode Displays the operation mode Generation ...

Страница 92: ...ctory default configuration 1 Navigate to Maintenance and click Restart Device The Factory Defaults page displays 2 Click Yes to reset the device to it s original factory defaults All changes that have been made will be lost even if you have issued a save Reset settings take effect after a system reboot Click No to cancel the reboot Figure 4 60 Factory Defaults 4 5 3 Software 4 5 3 1 Upload The fu...

Страница 93: ...5 4 Configuration 4 5 4 1 Save startup config Warning While the firmware is being updated Web access appears to be defunct The front LED flashes Green Off with a frequency of 10 Hz while the firmware update is in progress Do not restart or power off the device at this time or the switch may fail to function afterwards Item Description Image Displays the name of the firmware image since its last up...

Страница 94: ...tion and click Download The Download Configuration page displays 2 Click a listed file name to select it 3 Click Download Configuration to start the download Figure 4 64 Download Configuration Download of running config may require time to complete as the file must be prepared for download 4 5 4 3 Upload Configuration The function allows you to upload a file to the device with the exception of the...

Страница 95: ...n file to activate 1 Navigate to Maintenance Configuration and click Activate The Activate Configuration page displays 2 Click a file from the File Name table to select and activate 3 Click Activate Configuration to start the process Figure 4 66 Activate Configuration 4 5 4 5 Delete Configuration File The function allows you select a configuration file to delete 1 Navigate to Maintenance Configura...

Страница 96: ...Chapter 5 5Troubleshooting ...

Страница 97: ...the length of any twisted pair connection does not exceed 100 meters 328 feet R replacement letter for Ohm symbol Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter so the user can be guided towards possible solutions If the power indicator does not light on when the power cor...

Страница 98: ...ations are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2021 ...