62
EKI-8500 Series User Manual
The following table describes the items in the PSFP Flow Meter Configuration page.
4.3.5.4.2
Stream Filter
This function allows you to inspect the current PSFP configurations.
1.
Navigate to
Configuration
>
TSN
>
PSFP
and click
Steam Filter
.
The PSFP Stream Filter Configuration page displays.
Figure 4.36 PSFP Stream Filter Configuration
The following table describes the items in the PSFP Stream Filter Configuration
page.
Item
Description
Delete
Click
Delete
to remove the entry. It will be deleted during the next
save.
FMI ID
Enter a string to indicate the FlowMeterInstance parameter is an index
into the FlowMeterTable.
CIR
Enter a string to indicate the FlowMeterCIR parameter contains an
integer value that represents the CIR value for the flow meter, in bit/s.
CBS
Enter a string to indicate the FlowMeterCBS parameter contains an
integer value that represents the CBS value for the flow meter, in
octets.
EIR
Additional information required.
EBB
Additional information required.
CF
Additional information required.
CM
Additional information required.
Drop on Yellow
Additional information required.
Mark RED
Click to enable or disable (default) the FlowMeterMarkAllFramesRed
parameter contains a Boolean value that indicates whether, if the
MarkAllFramesRed function is enabled, all frames are to be discarded
(TRUE) or not (FALSE).
Add New Entry
Click
Add New Entry
to add Flow Meter entry.
Save
Click
Save
to save changes.
Reset
Click
Reset
to undo any changes made locally and revert to
previously saved values.
Item
Description
Delete
Click
Delete
to remove the entry. It will be deleted during the next
save.
SFI ID
Enter a string to indicate the Stream Filter Instance parameter is an
index into the StreamFilterTable.
Stream ID
The Stream Handle Spec parameter contains a stream identifier
specification value. A value of -1 denotes the wild card value; all
positive values denote stream identifier values.
Stream Enable
Click to enable or disable (default) the stream function.
Priority Spec
Click the drop-down menu to specify a priority value (value: -1
denotes the wild card value; zero or positive values denote priority).
Содержание EKI-8500 Series
Страница 1: ...User Manual EKI 8500 Series Managed TSN Switch ...
Страница 12: ...Chapter 1 1Product Overview ...
Страница 19: ...Chapter 2 2Switch Installation ...
Страница 35: ...Chapter 3 3Configuration Utility ...
Страница 41: ...Chapter 4 4Managing Switch ...
Страница 96: ...Chapter 5 5Troubleshooting ...