Integrated UPS (optional)
Page 74 of 122
DLT-V83 Series Manual V1.50
Advantech-DLoG
11.1.
Battery pack specification, UPS
Integrated UPS technical data
Bridging time
The integrated UPS can bridge an interruption of the main
supply typically for 10 minutes.
Requirement: the UPS is fully charged.
Operating temperature
-10 to +50 °C
Relative humidity
10% to 90% at 40 °C relative humidity, noncondensing
Mechanical vibration
and shock resistance
DLT-V8310 and DLT-V8312:
−
Class 5M3 according to EN 60721-3-5
−
US Highway Truck according to MIL-STD 810F
DLT-V8315:
−
Class 5M2 according to EN 60721-3-5
−
US Highway Truck according to MIL-STD 810F
Charging time
2.5 h (fully recharge a completely discharged battery).
The 10 minutes bridging time becomes available again after
a charge time of approx. 60 minutes. The UPS is
automatically recharged when the main supply voltage is
applied.
Charging temperature
0 to +45 °C (internal device temperature)
Storage temperature
-20 to +60 °C
Maximum output power
35 W
Input voltage
12 V
Output voltage
Typically 12 V
Battery voltage
7.2 V
Battery capacity
2200 mAh
11.2.
Charging the integrated UPS correctly
To charge the battery packs of the integrated UPS:
Connect the properly installed DLT-V83 to the main supply voltage.
NOTICE
: The cable cover of the DLT-V83 must be screwed together properly; the device
must be fully closed.
Charging time: 2.5 hours (fully recharge a completely discharged battery).
Do not remove the battery packs from the cable cover; do not charge with external chargers.
Do not connect damaged cable covers with battery packs to the DLT-V83; do not charge.
Battery packs become warm while charging; this is normal. However, if they become
excessively hot, immediately disconnect the DLT-V83 from the power source.
Do not continue to use the DLT-V83 if you notice an unusual level of heat or an unusual
smell during charging.
Provide for sufficient ventilation of the DLT-V83 when charging the battery packs.
11.3.
No repair/replacement of the battery packs
If the battery packs are faulty, the entire cable cover, including the integrated battery packs, must
be replaced.