Mechanical mounting, electrical connection
Advantech-DLoG
DLT-V83 Series Manual V1.50
Page 49 of 122
7.4.
Attaching the device mounting bracket (optional)
Observe the following information about the mounting brackets:
−
All support brackets and mounting parts supplied by Advantech-DLoG are only intended to be
used for attachment of the industrial PCs and the peripheral devices and may not be misused.
−
Only use suitable mounting brackets and screws permitted by Advantech-DLoG.
−
Ensure that ball-and-socket bases and mounting brackets are always attached correctly.
Please observe the mounting instructions supplied with the optional brackets.
7.5.
Electrical connection
WARNING
Risk of injury and damage due to improper electrical connection.
Only authorized skilled personnel are permitted to perform the electrical connection of the
DLT-V83. Moreover, specialized knowledge about battery packs and the applicable safety
regulations is also required for DLT-V83 industrial PCs with integrated UPS (optional).
If the electrical connection of the DLT-V83 is performed improperly, any DLoG GmbH warranty
for this device will be void.
Comply with the appropriate national installation regulations for the cable routing.
Do not connect/disconnect any cables during thunderstorms.
When working on the cable cover with UPS battery packs you must remove wristwatches,
rings or other metal objects.
Power supply unit fuse blows repeatedly
If the fuse of the integrated power supply units blows again immediately after replacement,
there is a risk of electrical shock:
Send in the DLT-V83 immediately for repair.
Electrical shock due to lack of disconnecting device.
DLT-V83 industrial PCs are not equipped with disconnecting devices that are accessible from
the outside; they do not have switches. To enable the devices to be quickly disconnected from
the power supply in emergency situations:
Install an easily accessible disconnecting device close to the device.
Make sure that the disconnecting device disconnects all power supply lines.
Please note
: For DLT-V83 devices with integrated UPS the device may be in operation despite
the disconnecting device being actuated, since it is supplied with power by the UPS.