Attaching the cable cover
Page 54 of 122
DLT-V83 Series Manual V1.50
Advantech-DLoG
8.
Attaching the cable cover
Before commissioning the DLT-V83, the associated cable cover must be attached. The protection
class of the DLT-V83 is only ensured if the cable cover is properly installed.
CAUTION
Risk of injury due to sharp-edged parts on the device.
The strain relief rail of the DLT-V83 can have sharp edges and cause cutting injuries.
Do not hold the DLT-V83 by the strain relief rail.
NOTICE: Physical damage
Device not sealed properly due to incorrect attachment of the cables and the cable
cover.
The protection class of the DLT-V83 is only ensured if the cable cover is properly installed.
Improper installation can result in liquid penetrating into the DLT-V83 during operation. There is
then a risk of short-circuiting, corrosion and wear.
8.1.
Overview of mounting steps
−
All cables that are connected to the DLT-V83 must be fit with the right cable grommets and
inserted in the cable outlets of the strain relief rail.
−
The cables are secured to the strain relief rail with cable clips. This prevents the cables from
being loosened at the connection points when too much force is exerted (e.g. during
scanning).
−
Unused cable entry holes for the strain relief rail must be closed off with dummy grommets.
−
The Advantech-DLoG cable cover must then be secured to the DLT-V83.