Operating the device
Page 22 of 122
DLT-V83 Series Manual V1.50
Advantech-DLoG
5.4.4.
Operating states
Status of LEDs
DLT-V83 Status
Supply voltage
(green)
Temperature
(red)
OFF
OFF
Initial state, idle time – waiting for a new
ignition signal or for the <Power> key after
switch off; no voltage supply.
OFF
FLASHING
Temperature sensor malfunctioning.
FLASHING
OFF
DLT-V83 is in standby mode (S3).
OFF
ON
Computer will only start if the temperature
in
the device
is in the range between -30 and
+62 °C again.
ON
OFF
Computer start-up/normal operational
state/shutdown delay time.
ON
ON
Temperature < -30 or > +70 °C.
ON
FLASHING
Temperature sensor malfunctioning.
Содержание DLT-V83 SERIES
Страница 1: ...www advantech dlog com Advantech DLoG DLT V83 Series DLT V83 Series Industrial PC Manual V1 50 Manual ...
Страница 115: ...Guidelines and certificates Advantech DLoG DLT V83 Series Manual V1 50 Page 115 of 122 19 9 Declaration of conformity ...