4.9.13
Performing Surface Check
The surface check function, which is only available in RAID levels 1 and 5, prevents double faults
from occurring when an error correcting code (ECC) fault is encountered while the ArrayMasStor is
operating in degraded mode. The ArrayMasStor has a function that corrects ECC faults by
overwriting the area containing the fault. The ArrayMasStor uses three methods to check data.
•
Surface check: This scans the entire data area for ECC faults and reconstructs and overwrites
errors
•
Parity regeneration: In RAID Level 5, this regenerates each parity-block and rewrites it to the
drives
•
Random check: This scans random storage areas for ECC faults and fixes the errors.
IMPORTANT !
It is strongly recommended that these checks implement to
ensure data and parity consistency.
From the change configuration menu, use the up or down button to
display SURFACE CHECK. Press the select button to access this
menu.
Use the up or down button to display the desired mode, then press the
select button to confirm. Pressing the cancel button returns the
display to the previous menu.
Use up or down button to choose parity check method. Press the
select button to confirm.
Use up or down button to choose random check method. Press the
select button to confirm.
Press the select button to confirm, or press the cancel button to return
to the display to the previous menu.
The selected check mode starts and its progress is shown in percent.
When the check is completed, the display returns to the main menu.
CHANGE CONFIG
-SURFACE CHECK
CHECK MODE
PARITY REGEN
CHECK MODE
RANDOM CHECK
START CHECK
OR X TO CANCEL
CHECK MODE
SURFACE CHECK
SURFACE CHECK
PROGRESS 0%