Total Access 600R System Manual
Section 4 User Interface Guide
61200600L1-1A
© 2002 ADTRAN, Inc.
65
I
NTERFACES
(T1[0]) > C
ONFIG
> F
ORMAT
This sets the frame format for the T1 interface. The setting must match the frame format of the circuit to
which the interface is connected. Choices are
ESF
,
SF
,
SLC96 A
LARM
-16
, and
SLC96 A
LARM
-13
. Extended
Superframe (
ESF
) provides a non-disruptive means of full-time monitoring on the facility datalink (FDL).
Default is
ESF
.
I
NTERFACES
(T1[0]) > C
ONFIG
> L
INE
C
ODE
This sets the line code for the T1 interface. The setting must match the line code of the circuit to which the
interface is connected. Choices are
B8ZS
(bipolar with 8-zero substitution) and
AMI
(alternate mark
inversion). Default is
B8ZS
.
I
NTERFACES
(T1[0]) > C
ONFIG
> E
QUALIZATION
Select the line build out for the T1 interface. These are attenuation settings. 0 dB is the strongest signal and
the other settings make the T1 transmit signal weaker. The setting of this field depends on whether the
circuit is provisioned for DS1 by the telephone company. The choices are
0 dB
,
-7.5
d
B
,
-15 dB
,
-22 dB
.
Default is
0 dB
.
I
NTERFACES
(T1[0]) > C
ONFIG
> CSU L
PBK
Choices are
E
NABLE
,
D
ISABLE
, and
D
ISABLE
A
LL
. Default is
E
NABLE
. This allows the unit to either respond
or not respond to CSU loop up commands.
I
NTERFACES
(T1[0]) > S
TATUS
Displays the T1 status including performance data and alarm histories.
I
NTERFACES
(T1[0]) > S
TATUS
> P
ERFORMANCE
Displays the T1 performance data.
I
NTERFACES
(T1[0]) > S
TATUS
> P
ERFORMANCE
> T
IME
F
RAME
Choices are
C
URRENT
,
15 M
IN
, and
24 H
R
. Default is
C
URRENT
. The performance fields -- either
C
URRENT
,
15 M
IN
, or
24 H
R
. -- provide status on key performance measures as specified in ANSI T1.403 and AT&T
TR 54016 for each of the T1 ports. When
C
URRENT
is chosen, the performance data for the current 15
minute window is shown.
I
NTERFACES
(T1[0]) > S
TATUS
> P
ERFORMANCE
> C
LEAR
Clears information for the selected port. Press
<Enter>
when the cursor is over this field to clear the data.
SF
is equivalent to the D4 frame format.
Содержание TOTAL ACCESS 600R
Страница 1: ...TOTAL ACCESS 600R System Manual 4200600L1 TDM Total Access 600R TDM 61200600L1 1A December 2002...
Страница 4: ...4 2002 ADTRAN Inc 61200600L1 1A Revision History This is the first issue of this manual...
Страница 16: ...Section 1 System Description Total Access 600R System Manual 16 2002 ADTRAN Inc 61200600L1 1A...
Страница 28: ...Section 2 Engineering Guidelines Total Access 600R System Manual 28 2002 ADTRAN Inc 61200600L1 1A...
Страница 30: ...Section 3 Network Turnup Procedure Total Access 600R System Manual 30 2002 ADTRAN Inc 61200600L1 1A...
Страница 34: ...Section 3 Network Turnup Procedure Total Access 600R System Manual 34 2002 ADTRAN Inc 61200600L1 1A...
Страница 128: ...Section 5 DLP Index Total Access 600R System Manual 128 2002 ADTRAN Inc 61200600L1 1A...
Страница 134: ...134 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 002 Total Access 600R System Manual...
Страница 138: ...138 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 003 Total Access 600R System Manual...
Страница 144: ...144 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 005 Total Access 600R System Manual...
Страница 152: ...152 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 007 Total Access 600R System Manual...
Страница 160: ...160 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 009 Total Access 600R System Manual...
Страница 180: ...180 2002 ADTRAN Inc 61200600L1 1A Section 5 DLP 015 Total Access 600R System Manual...
Страница 190: ...Section 6 ADTRAN Utilities Total Access 600R System Manual 190 2002 ADTRAN Inc 61200600L1 1A...
Страница 192: ...Section 7 MIB Total Access 600R System Manual 192 2002 ADTRAN Inc 61200600L1 1A...
Страница 196: ...Section 7 MIB Total Access 600R System Manual 196 2002 ADTRAN Inc 61200600L1 1A...