Unit Installation
NetVanta 3000 Series Hardware Installation Guide
76
Copyright © 2010 ADTRAN, Inc.
61200860L1-34AA
Mounting Options
The NetVanta 3120, NetVanta 3130, and NetVanta 3200 can be installed in a wallmount or tabletop
configuration. The NetVanta 3205 and NetVanta 3305 can be installed in a tabletop, wallmount, or 19-inch
rackmount configuration. The NetVanta 3430 and NetVanta 3448 can be installed in a tabletop or
rackmount configuration.
For tabletop mounting, you can attach rubber mounting feet to the bottom of the unit if desired. The
following sections provide step-by-step instructions for rack mounting and wall mounting.
Rack Mounting NetVanta 3000 Series
The NetVanta 3205, NetVanta 3305, NetVanta 3430, NetVanta 3448, NetVanta 3450, and NetVanta 3458
are 1U-high, rack-mountable units that can be installed into 19-inch equipment racks. Follow these steps to
mount the NetVanta 3000 Series unit into a rack:
If you have purchased P/N 4200368L1, which includes the VPN Accelerator Card with the
NetVanta 3305, install the card before mounting the unit. Refer to
Installing the NetVanta
VPN Accelerator Card (included in P/N 4200368L1) on page 95
.
Instructions for Rack Mounting the NetVanta 3000 Series
Step
Action
1
To allow proper grounding, scrape the paint from the rack around the mounting holes where the NetVanta
3000 Series will be positioned.
2
Position the NetVanta 3000 Series in a stationary equipment rack. This unit occupies 1U of space.
3
Have an assistant hold the unit in position as you install two mounting bolts through the unit’s brackets and
into the equipment rack using a #2 phillips-head screwdriver.
4
Proceed to the steps given in
Supplying Power to the Unit on page 83
.
•
If installed in a closed or multi-unit rack assembly, the operating ambient temperature
of the rack environment may be greater than room ambient temperature. Therefore,
consideration should be given to installing the equipment in an environment compatible
with the maximum ambient temperature specified by the manufacturer.
•
Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
•
Be careful not to compromise the stability of the equipment mounting rack when
installing this product.
•
Consideration should be given to the connection of the equipment to the supply circuit
and the effect that overloading the circuit might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment nameplate ratings should be
used when addressing this concern.
•
Reliable grounding of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the
branch circuit (e.g., use of power strips).