Dual Rackmount
Figure 19. Rack Mounting the NetVanta 1131 Using the Dual Mounting Tray
Instructions for Rack Mounting the NetVanta 1131 (Dual Mount)
Step
Action
1
Install the dual mounting tray (P/N 1700534F1 purchased separately) in a stationary equipment
rack using the mounting brackets and four screws provided.
2
To allow proper grounding, scrape the paint from the rack around the mounting holes where the
tray will be positioned.
3
Position two NetVanta 1131 units side by side on the dual mounting tray lining up the holes in
the front of the units with the holes in the tabs on the front of the tray (see
Figure 19
).
Important!
To avoid damaging the unit when attaching it to the dual mounting tray, use only the
screws supplied with the tray.
4
Insert the provided screws through the tabs into the units securing them with a screwdriver.
5
Proceed to the steps given in
Connecting the NetVanta 1131 and the NetVanta Switch on
page 44
.