NetVanta 1534/1544 Series
NetVanta 1131 RPS/EPS
61702590G1-34E
Copyright © 2013 ADTRAN, Inc.
37
5.
NETVANTA 1131 RPS/EPS
The NetVanta 1131 RPS/EPS has three RPS outputs and one EPS output for use with RPS/EPS equipped
NetVanta switches.
Important: Refer to the NetVanta 1131 product on
www.adtran.com
for a list of supported
switches.
The RPS outputs provide redundant or backup power for a switch’s internal power supply. The EPS
output provides backup power for a Power over Ethernet (PoE) switch’s internal PoE supply, as well as extended
or supplemental power to provide full PoE for 48-port switches (up to 740 W of power).
The NetVanta 1131 does not activate RPS power until a failure is detected on the switch for which it is providing
redundancy. Once RPS power is being supplied to a switch, if a second switch fails, the power will not transfer
to the second switch. In the event that multiple connected switches lose power simultaneously, RPS power will
be supplied first failed switch detected.
The NetVanta 1131 is housed in a 1U-high, metal enclosure that can be wall mounted, rack mounted singly
using the provided rackmount brackets, or rack mounted two side by side using the optional dual mounting tray
(P/N 1700534F1).
NetVanta 1131 Series Shipping Contents
Each NetVanta 1131 RPS/EPS unit is shipped in its own cardboard shipping carton. Open each carton carefully,
and avoid deep penetration into the carton with sharp objects.
After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit,
immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the
Support
page on
the ADTRAN website at
http://www.adtran.com/support
).
Domestic shipments of the NetVanta 1131 include the following items:
•
NetVanta 1131 base unit
•
Two 19-inch rack mounting brackets and eight screws
•
Two wall mounting brackets and four screws
•
A detachable power cable with a grounded, three-prong plug
•
Quick start guide
International shipments of the NetVanta 1638 include the following items:
•
NetVanta 1131 base unit
•
Two 19-inch rack mounting brackets and eight screws
•
Two wall mounting brackets and four screws
•
All necessary power cords
•
Quick start guide
•
The NetVanta 1131 and the NetVanta switch with which it is associated should be
installed in a restricted access location as described in UL 60950-1.
•
Under full load, the NetVanta 1131 may be hot to the touch.