61200410L2-1A

ESU LT User Manual

 21

Chapter 2

Installation

UNPACK, INSPECT, POWER UP

Receipt Inspection

Carefully inspect the ESU LT

 

for any shipping damage. If damage 

is suspected, file a claim immediately with the carrier and then 
contact ADTRAN Customer Service. If possible, keep the original 
shipping container for use in shipping the ESU LT

 

back for repair 

or for verification of damage during shipment.

ADTRAN Shipments Include

The following items are included in the ADTRAN shipment:

ESU  LT

 

unit

DB-15 to BNC adapter

ESU LT User Manual

DB-15 to solid conductor cable

Customer Provides

DTE cable(s)

Cable for supervisory port, if used

Power cable

Cable for connection to the 120

 DB-15 network interface

Содержание 1200410L2

Страница 1: ...61200410L2 1A April 2004 ESU LT User Manual Part Number 1200410L2...

Страница 2: ...manual are current as of the date of publication ADTRAN reserves the right to change the contents without prior notice In no event will ADTRAN be liable for any special incidental or consequential dam...

Страница 3: ...n a cordless type during an electrical storm There is a remote risk of shock from lightning 3 Do not use the telephone to report a gas leak in the vicinity of the leak 4 Use only the power cord power...

Страница 4: ...ual may cause harmful interference to radio frequencies Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the...

Страница 5: ...embourg Netherlands Norway Poland Portugal Slovenia Spain Sweden Yugoslavia 250 VAC 10A HAR CEE 7 7 IEC 60320 C13 Australia China 250 VAC 10A V76419 AS 3112 IEC 60320 C13 Denmark 250 VAC 10A HAR Afsni...

Страница 6: ...Warranty and Customer Service ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service Warranty information can...

Страница 7: ...pment currently in house or possible fees associated with repair Identify the RMA number clearly on the package below address and return to the following address Pre Sales Inquiries and Applications S...

Страница 8: ...types and levels of installation and maintenance services which allow you to choose the kind of assistance you need This support is available at For questions call the ACES Help Desk Training The Ent...

Страница 9: ...Inspection 21 ADTRAN Shipments Include 21 Customer Provides 21 Power Connection 22 Grounding Instructions 22 Identification of Rear Panel Layout 24 ESU LT Rear Panel 24 ESU LT Interfaces 25 Network In...

Страница 10: ...m 34 Chapter 4 Status Menu 35 STATUS 35 NI PERF RPTS 36 CURR ERR ALM 37 Alarms and Errors 37 ERR ALM Hist 39 Chapter 5 Configuration Menu 41 CONFIG 41 Network NI 42 Framing 42 Line Code 43 CRC 4 43 NF...

Страница 11: ...est Menu 57 TEST 57 Network Tests 58 Loopback Tests 58 Network Interface Loopbacks 58 DTE Interface Loopbacks 59 Local Loopbk 60 Remote Loopbk 60 Test Pattern 60 CLR Errors 61 Insert QRSS or 511 Error...

Страница 12: ...Table of Contents 12 ESU LT User Manual 61200410L2 1A...

Страница 13: ...ss of Signal Current Errors Alarms Screens 37 Figure 4 4 Clear History Screen 39 Figure 5 1 Configuration Menu 41 Figure 5 2 Network Timed Clock Source 44 Figure 5 3 Internal Timing Clock Source 45 Fi...

Страница 14: ...List of Figures 14 ESU LT User Manual 61200410L2 1A...

Страница 15: ...he Time Date 54 Table 8 1 Initiating a Remote Loopback 66 Table 8 2 DTE Data Rate vs TS0s 67 Table 8 3 Network Pin Assignments 69 Table 8 4 Control Chain In Pin Assignments 70 Table 8 5 Control Chain...

Страница 16: ...List of Tables 16 ESU LT User Manual 61200410L2 1A...

Страница 17: ...E1 or FE1 facilities This family of ESU products includes the following ESU LT E1 CSU DSUs with a single Nx56K 64K serial port ESU 120e Same as the ESU LT with the added feature of a G 703 drop port a...

Страница 18: ...36 and X 21 electrical in terfaces Selectable timing from the network the Nx56 64 DTE port or internally All ones all zeros 511 QRSS and 1 8 test patterns Extensive self testing and monitoring ensure...

Страница 19: ...e selected as contiguous or alternate Figure 1 2 shows a simple bridge application Figure 1 2 Simple Bridge Application on an E1 or FE1 Circuit High speed serial interface ESU LT ESU LT Bridge Router...

Страница 20: ...Chapter 1 Introduction 20 ESU LT User Manual 61200410L2 1A...

Страница 21: ...er Service If possible keep the original shipping container for use in shipping the ESU LT back for repair or for verification of damage during shipment ADTRAN Shipments Include The following items ar...

Страница 22: ...e product or system are all to be of a grounding type and the equipment grounding conductors serving these receptacles are to be connected to earth ground at the service equipment A supplementary equi...

Страница 23: ...d grounding conductors are acceptable A covered or insulated grounding conductor shall have a continuous outer finish that is either green or green with one or more yellow stripes The supplemental gro...

Страница 24: ...el NX 56 64 NETWORK CHAIN IN CHAIN OUT MON CONTROL 90 240 VAC 50 60 HZ 24A 1 2 3 4 5 6 7 Number Identification for ESU LT Rear Panel Name Description 1 Network E1 FE1 network interface 2 MON Monitor B...

Страница 25: ...Interface NI port provides the connection to the E1 This port complies with the applicable ANSI and CCITT standards The 120 DB 15 interface adapter provided may be used for the NI For more informatio...

Страница 26: ...nce which sets up the unit Self Test The self test checks the integrity of the electronic components internal operation by performing memory tests and by sending and verifying data test patterns throu...

Страница 27: ...ed failures the LCD momentarily displays ALL TESTS PASSED If a failure is detected during the self test process the failure is displayed in the LCD window The automatic self test consists of the follo...

Страница 28: ...Chapter 2 Installation 28 ESU LT User Manual 61200410L2 1A...

Страница 29: ...equent pages Figure 3 1 Front Panel Layout ESU LT CS TEST ALM TD PWR ERR RD RS ENTER CANCEL 1 2 3 4 5 6 7 8 9 10 12 11 13 Table 3 1 Front Panel Descriptions Item Name Description 1 PWR LED ON when pow...

Страница 30: ...activate the submenu items available in the current menu When the submenu items are scrolled the flashing cursor in dicates the active parameters 12 Enter Selects active menu items To select a menu it...

Страница 31: ...ains four options STATUS CONFIG UTIL and TEST Status The STATUS menu displays all relevant information for the network and DTE interfaces For detailed information on status options see Status Menu on...

Страница 32: ...As an example Table 3 2 describes how to activate the NETWORK menus from the CONFIG menu Figure 3 2 Cursor on Menu Item Figure 3 3 Submenu Fields Table 3 2 Activating the Network Menus from the Confi...

Страница 33: ...e cursor moves to the data field to the right of the submenu item name 2 Using the arrows scroll to scan the available value settings The value settings display one at a time in the data field positio...

Страница 34: ...of the ESU LT using a graphic interface The T Watch PRO program displays the same status and performance data as the front panel LCD This data is displayed as tables and graphs The T Watch PRO program...

Страница 35: ...SS OF SIGNAL DM LOSS OF FRAME UAS LOSS OF TS16 MF 2 CURR ERR ALM LOSS OF CRC 4 1 STATUS AIS RECEIVED CLEAR HISTORY TS16 AIS RCVD LOSS OF SIGNAL REMOTE ALARM LOSS OF FRAME REMOTE MF ALARM LOSS OF TS16...

Страница 36: ...nly cleared as previously discussed Only the user copy of performance data is cleared See Figure 4 2 Continue with standard operating procedures to exit the display Figure 4 2 Severely Errored Seconds...

Страница 37: ...e Figure 4 3 Figure 4 3 Loss of Signal Current Errors Alarms Screens The up and down arrows are used to access the complete display of the errors alarms that are currently active Alarms and Errors The...

Страница 38: ...S RCVD Unframed ones being received in TS16 on network interface Remote Multiframe Alarm transmitted out network interface REMOTE ALARM Remote alarm signal Bit 3 of NFAS word being received at network...

Страница 39: ...r viewing history of errors and alarms If an alarm has occurred since the last CLEAR HISTORY selection the menu is active If an alarm has not occurred the menu is inactive see Figure 4 4 Figure 4 4 Cl...

Страница 40: ...Chapter 4 Status Menu 40 ESU LT User Manual 61200410L2 1A...

Страница 41: ...of the time slots and the port parameters See Figure 5 1 Figure 5 1 Configuration Menu 1 FRAMING 1 NETWORK NI 2 LINE CODE 3 CRC 4 4 NFAS WORD 5 RFA GEN 6 TIMING MODE 1 POSITION 1 CONTROL PORT 2 MODEM...

Страница 42: ...ed in timeslot 0 of even frames Odd numbered frames may contain the Not FAS word NFAS in timeslot 0 The ESU LT can be configured to require the NFAS word for frame sync In CCS mode there are 31 channe...

Страница 43: ...DATA INVERT INBAND Choices CCS CAS TS16 UNFRAMED Line Code Selects either Alternate Mark Inversion AMI or High Density Bipolar Order 3 HDB3 line coding AMI provides a 12 5 minimum ones pulse density a...

Страница 44: ...DTE Network Timing The network is the source of timing The received data clocking is looped back to the network where it is used to determine the transmission timing This option is also referred to as...

Страница 45: ...driver circuits where one end is set to network and the other to internal See Figure 5 3 Figure 5 3 Internal Timing Clock Source DTE Timing The DTE is the source of timing The ESU LT uses the incoming...

Страница 46: ...nd initializes a modem and the control port data rate It also sets baud rate for communications with a PC or modem Position Determines whether this ESU LT is at the head of a chain of units directly c...

Страница 47: ...ines whether alarm conditions should automatically send alarm messages traps to the controlling PC The setting is for this unit or for slaves if this unit is a master Choices ENA DISA Output Selects w...

Страница 48: ...r the inband channel nor the TS0 management channel is utilized Inband Selects the 8K inband channel as the management channel When this option is selected the first time slot occupied operates in 56K...

Страница 49: ...uld drop from 128K to 64K TS0 management is not available in unframed mode Port Port Configuration The menu item PORT is used to select and then to configure the parameters associated with the high sp...

Страница 50: ...ically selects between the INTERNAL and INT INV settings If the DTE provides a clock with TX data the clock selection is set to EXTERNAL The ESU LT depends on an externally supplied clock to accept th...

Страница 51: ...e Table 5 1 FORCE ON DCD Data Carrier Detect Indicates to the DTE that a valid signal is being received at the Network Interface Choices NORMAL see Table 5 1 FORCE ON DSR Data Set Ready This signal in...

Страница 52: ...0L2 1A Inband If Inband is selected as the management channel set to NORMAL or AUTO In NORMAL mode the channel is always enabled In AUTO mode the channel is enabled only when commands are sent from T...

Страница 53: ...tting all parameters to factory values and re initializing the unit This menu is also used to view the unit s software revision and the unit ID setting Figure 6 1 Utility Menu 1 TIME DATE TIME HH MM S...

Страница 54: ...6 2 To edit the date and time follow the steps outlined in Table 6 1 Figure 6 2 Time Date Screen Table 6 1 Editing the Time Date To Do this Record the entry and move to the next editing position Pres...

Страница 55: ...eeded Reinit Unit The REINIT UNIT submenu is used to reinitialize the unit This menu item is not used to restore the factory default settings for all parameters Address ADDRESS is used to access the c...

Страница 56: ...s LOCKED option settings can be viewed but not changed The user selected passcode is not required to lock the keypad When UNLOCKED is selected the user is required to enter the four digit passcode If...

Страница 57: ...n will disrupt some of the normal operation See indi vidual menu items concerning tests before executing NO LOOPBACK 1 LOCAL LOOPBK LINE ON PAYLOAD ON 2 REMOTE LOOPBK NO LOOPBACK 1 NETWORK TESTS FE1 L...

Страница 58: ...or remotely by using special in band codes AT T D4 network loop up and loopdown codes Additionally the loopbacks can be remotely controlled by means of out of band commands by the E1 ESF FDL or from T...

Страница 59: ...ial interface offers a DTE loopback See Figure 7 4 DTE Loopback Loops all data from the DTE back towards the DTE This loopback may be initiated by using the front panel or T Watch PRO commands The DTE...

Страница 60: ...framed mode TEST PATTERN Sets the pattern for the test and initiates the transmission of the pattern There are four patterns available The test is terminated by selecting NO PATTERN 1 8 ALL TS0s The 1...

Страница 61: ...S CLR ERRORS has two functions 1 To clear out the 511 error total when you press Enter 2 To display a total of the 511 errors If 511 errors are being received the display is updated accordingly See Fi...

Страница 62: ...displayed in the LCD window see Figure 7 6 The following board level tests are performed during self test Figure 7 6 Self Test Results Screen Order Test 1 RAM tests EPROM checksum 2 On board data path...

Страница 63: ...ort Tests Port Tests are used to control the activation of a DTE loopback This test loops data received at the high speed serial interface back towards the DTE See Figure 7 7 Figure 7 7 Loopback Setti...

Страница 64: ...Chapter 7 Test Menu 64 ESU LT User Manual 61200410L2 1A...

Страница 65: ...up code sent over the E1 circuit The remote unit will loop the network interface providing a path for data from the local unit over the circuit and back again Sending a known test pattern over this l...

Страница 66: ...be selected with the up and down arrows 5 Use the up and down arrows to place the cursor on REMOTE LOOPBK 6 Press Enter to select FE1 Loopback 7 Use the up and down arrows to select TEST PATTERN 8 Pr...

Страница 67: ...Table 8 2 DTE Data Rate vs TS0s OF TS0s N DTE RATE 56K DTE RATE 64K N 1 56K 64K N 2 112K 128K N 3 168K 192K N 4 224K 256K N 5 280K 320K N 6 336K 384K N 7 392K 448K N 8 448K 512K N 9 504K 576K N 10 560...

Страница 68: ...N 20 1120K 1280K N 21 1176K 1344K N 22 1232K 1408K N 23 1288K 1472K N 24 1344K 1536K N 25 1400K 1600K N 26 1456K 1664K N 27 1512K 1728K N 28 1568K 1792K N 29 1624K 1856K N 30 1680K 1920K N 31 1736K 1...

Страница 69: ...nector The network connections are as follows Connector Type 15 pin female D connector Table 8 3 Network Pin Assignments Pin Name 1 Tx data output 2 Frame ground 3 Rx data input 4 Frame ground 5 Frame...

Страница 70: ...in or another ESU chain out See Table 8 4 for the pin assignment for this connector Connector Type RJ 48 Table 8 4 Control Chain In Pin Assignments Pin Name Description 1 GND Ground connected to unit...

Страница 71: ...r Type RJ 48 Table 8 5 Control Chain Out Pin Assignments Pin Name Description 1 GND Ground connected to unit chassis Connect to GND of next unit pin 1 2 UNUSED 3 TXDATA Data transmitted to chained uni...

Страница 72: ...d DTE 8 CF A 109 Received Line Detector DCD A DCE 9 DD B 115 Receiver Element Timing RC B DCE 10 CF B 109 Received Line Detector DCD B DCE 11 DA B 113 External Clock B ETC B DTE 12 DB B 114 Transmit E...

Страница 73: ...CE 6 DSR 107 DSR Data Set Ready DCE 7 GND 102 Signal GND DTE 8 DCD 109 Rec Line Det DCE 9 RC B 115 Rx Timing B DCE 10 Not Used 11 ETC B 113 External Clock B DTE 12 TC B 114 Tx Timing B DCE 13 Not Used...

Страница 74: ...4 C RTS or RR 5 D CTS 6 E DSR 7 B Signal GND 8 F Rec Line Sig Det DCD 9 X Rx Signal Timing B 10 Not Connected 11 W External Clock B 12 AA Tx Signal Timing B 13 Not Connected 14 S Tx Data B 15 Y Tx Si...

Страница 75: ...Pin Name Description Source 1 Protective GND shield n a 2 T A Transmit A DTE 3 R A Receive A DCE 4 C A Control A DTE 7 G Signal GND n a 8 I A Indication A DCE 9 12 S B Signal Timing B DCE 10 I B Indi...

Страница 76: ...er Cable DB 25 to X 21 DB 15 Connector Name DB 25 DA15S Protective GND Shield 1 1 Signal GND 7 8 Control A 4 3 Control B 19 10 Indication A 8 5 Indication B 10 12 Transmit A 2 2 Transmit B 14 9 Receiv...

Страница 77: ...ror alarm menu 37 D data port interface pinouts 72 data rate chart 67 DTE interface loopbacks 59 DTE loopback 59 DTE timing config menu 45 E error alarm history menu 39 ESU LT 25 features 18 functiona...

Страница 78: ...ter 74 control in chain in 70 control chain out 71 data port interface 72 network connections 69 Nx56 64 for v 11 x 21 mode 75 Nx56 64 for V 35 Mode 73 port configuration 49 port tests DTE loopback ac...

Страница 79: ...Index 61200410L2 1A ESU LT User Manual 79 menu tree 53 reinitializing the unit 55 setting passcode for T Watch PRO and keypad lockout 55 setting system parameters 53 W wiring 69...

Страница 80: ...Index 80 ESU LT User Manual 61200410L2 1A...

Отзывы: