ADLY MOTO
13-3
ELECTRICAL DEVICE
Ignition Coil Conduction Test
Θʳ
Check first coil resistance of ignition
terminal.
Standard valve (20
к
): 0.1
̑˃ˁˆӨʳ
ʳ
Θ
Check second coil resistance between
spark plug cap & (-) terminal.
Standard valve : 10.5
̑˄ˈˁˈʳ˾Өʳ
ʳ ʳ ʻ̆̃˴̅˾ʳ̃˿̈˺ʳ˶˴̃ʳ˼́̆̇˴˿˿˸˷ʼʳ
Θ
Remove spark plug cap from high tension
coil.
Θ
Check second coil resistance between high
voltage & (-) terminal.
Standard valve : 2.5
̑ˇʳ˾Өʳ
(without spark plug cap)
Remove main switch
Θ
Disconnect main switch wire.
Θ
Pull the main switch Bracket inside front cover.
Θ
Push the stopper on main switch underneath front cover then push out the main switch.
Check main switch
Remove connector of main switch wire, check conductivity between each terminal.
Color R Bk
OFF
ON
Ϥ
Ϥ
WARNING:
Check ignition status with
performance tester due to this test has its
own standard.