Operation Theory
•
31
(M_Counter=M=3, PSC_Counter=N=1)
Acquisition_in_progress
Scan_start
ADCONV
Acquired data
Acquired & stored data
(M+N scans)
Operation start
Trigger
M scans before
trigger
N scans
after trigger
Trigger signals which occur in the shadow
region(the first M scans) will be ignored
The first M scans
Post Scan Count
1
0
Figure 14: Middle trigger with M_enable = 1
If the trigger event occurs when a scan is in progress, the stored N scans of
data would include this scan, as illustrated in Fig 15.
(M_Counter=M=2, PSC_Counter=N=2)
Acquisition_in_progress
Scan_start
ADCONV
Acquired data
Acquired & stored data
(M+N scans)
Trigger occurs when a scan is in progress
Operation start
Trigger
M scans before
trigger
N scans at and
after trigger
2
Post Scan Count
1
0
Figure 15: Middle trigger (trigger occurs when a scan is in
progress)