56
•
Operation Theory
Category
Timing signal
Functionality
Constraints
EXTTIMEBASE
Replace the internal
TIMEBASE
1. TTL-compatible
2. 1MHz to 40MHz
3. Affects on both A/D
and D/A operations
EXTDTRIG
External digital
trigger input for A/D
operation
1. TTL-compatible
2. Minimum pulse width
= 20ns
3. Rising edge or falling
edge
Dedicated
input
EXTWFTRG
External digital
trigger input for D/A
operation
1. TTL-compatible
2. Minimum pulse width
= 20ns
3. Rising edge or falling
edge
Replace the internal
ADCONV
1. TTL-compatible
2. Minimum pulse width
= 20ns
3. Rising–edge sensitive
only
AFI[0]
(Dual functions)
Replace the internal
SCAN_START
1. TTL-compatible
2. Minimum Pulse width
> 2/TIMEBASE
Multi-function
input
AFI[1]
Replace the internal
DAWR
1. TTL-compatible
2. Minimum pulse width
= 20ns
3. Rising–edge sensitive
only
Table 13: Auxiliary function input signals and the corresponding
functionalities
EXTDTRIG and EXTWFTRIG
EXTDTRIG and EXTWFTRIG are dedicated digital trigger input signals for
A/D and D/A operations respectively. Please refer to section 4.5.3 for d e-