background image

Page  9 

 

The user can set the temperature according to different food. It is recommended that the normal working temperature should be 
180--250

. It would take approximately 22~26 minutes for the oven temperature to reach 250

 

When the temperature reached the pre-set temperature, the thermostat would cut-off the power supply automatically.   

 

When the temperature is lower than the pre-set value, the thermostat would restart working.   

 

After finishing a day’s work, rotate the controlling knob to the OFF position.   

 

4. Installation 

4.1 General information 
The manufacturer cannot be held liable for any damage to property or injury to persons deriving from installation errors or from 

inappropriate use of the appliance and is not responsible for any faults caused by defective installation. In such cases, the warranty shall 

be null and void. 

 
The appliance should be installed, serviced, and started up only by an authorized installer, who must comply with the safety regulations 

in force in the plac8 

e where the appliance is being installed. 

 

4.1.1 Regulatory installation conditions 

For your information, we remind you that all appliances installed in public assembly buildings must meet all the requirements listed below. 

The appliance should be both installed and serviced in accordance with all applicable regulations and standards in force, namely: 

 

 

Safety regulations on fire hazard and panic in public assembly buildings. 

 

General regulations applicable to all appliances; 

 

Systems burning combustible gas and liquefied hydrocarbons. 

 

Then, follow the specific regulations according to the type of gas being used. 

 

 

Heating, ventilation, refrigeration, air conditioning, and generation of steam and hot water for sanitary use; 

 

Installation of foodservice cooking appliances; 

 

Specific regulations applicable to each type of public assembly building (hospitals, shops, etc.). 

 
4.2 Exhausting fumes 

The appliance should be installed in a well-ventilated area, if possible under a vent hood, in compliance with all applicable regulations in 

force. This will ensure that the flue gas can be completely exhausted. 

 

4.3 Possible environmental interference 

If the appliance is installed with its sides next to flammable walls (made of wood or similar materials) or to heat-sensitive walls (made of 

plasterboard or similar materials), suitable protective measures should be taken to keep such walls undamaged. Therefore, apply a 
coating to insulate the walls from radiative heat or keep a minimum clearance of 200 mm (8") from the side and back panels of the 

appliance. 

Содержание RGR24X

Страница 1: ...t before installation commences 2 This manual must be handed to the end user after installation and commissioning 3 These instructions are only valid if the country code appears on the appliance If th...

Страница 2: ......

Страница 3: ...tion Construction features Cooking surfaces Electric oven 4 Installation 9 General information Regulatory installation conditions Exhausting fumes Possible environmental interference Preparing for ins...

Страница 4: ...ing minimum output Functional check 6 Operating instructions 15 Before using the appliance Preparing the appliance for use Using the appliance Operating controls Turning the open burners on and off Tu...

Страница 5: ...RGR36X 914 855 1524 1 3mm 1 2mm 1 1mm 1 9mm 1 9mm 36kW 36kW 39kW 36kW 36kW RGR24X 609 855 1524 1 3mm 1 2mm 1 1mm 1 9mm 1 9mm 24kW 24kW 26kW 24kW 24kW Model Oven Dimension mm OVEN orifice size heat inp...

Страница 6: ...Page 5 d Exploded Drawing RGR36X...

Страница 7: ...ntrol panel 1 39 oven thermocouple 1 13 oven door assy 1 40 pilot 1 14 left door decoration bar 1 41 U burner 1 15 front bottom hinge assy 2 42 1 4 to 10 transfer connector 1 16 bottom door decoration...

Страница 8: ...sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Child...

Страница 9: ...towards the operator 3 2 2 Cooking surfaces 1 Unit RGR24X with 4 stabilized flame gas burners made of cast iron and controlled by pilot flames Unit RGR36X with 6 stabilized flame gas burners made of c...

Страница 10: ...ings must meet all the requirements listed below The appliance should be both installed and serviced in accordance with all applicable regulations and standards in force namely Safety regulations on f...

Страница 11: ...4 8 Disposing of packaging materials All packaging materials must be disposed of in compliance with applicable local regulations in force where the appliance is being installed Packaging materials sh...

Страница 12: ...f the appliance which should be closed whenever the appliance is not in operation After connecting the appliance to the gas system check for leaks at joints and pipe fittings to do so use soapy water...

Страница 13: ...pliance 2 Check for gas leaks 3 Check for flame stability throughout the whole control range by going from high to low 4 14 Staff training Inform all personnel assigned to operate the appliance on how...

Страница 14: ...pes of gas you will need to adjust the screw as required until you obtain a stable and even flame Proceed as follows Unscrew the screw Connect a liquid filled pressure gauge for example a U shaped pre...

Страница 15: ...n the piping It may take about 10 seconds 6 2 2 4 Light it with long match lighter hold the knob 10 seconds until the flame is stable Adjust the knob to high flame position for complete ignition of th...

Страница 16: ...emove the most stubborn food residues Use rather pads or spatulas made of stainless steel or softer non ferrous materials Stagnation of substances having acid components such as vinegar lemon juice sa...

Страница 17: ...pliance To avoid the appearance of corrosion spots make sure that any salt residues left on the internal and external walls are carefully removed 6 3 3 Periodic maintenance Only qualified personnel ar...

Страница 18: ...Page 17 Aforementioned failures are just for reference If any failure occurs please stop using and inform professional technician to check and repair...

Страница 19: ...GR24X RGR36X Imported By ADEXA DIRECT LIMITED GROUND FLOOR UNIT 1 214 PURLEY WAY CROYDON CR0 4XG LONDON UNITED KINGDOM Serial Number Year of Manufacture Brand ADEXA Application of Council Directive s...

Отзывы: