Page 13
Gas Type
Oven Pilot
Nozzle NG
Oven
Pilot Nozzle
LPG
RGR36X
0.4mm 0.25mm
RGR24X
0.4mm 0.25mm
Note: When replacing the nozzles, please follow the requirements described in the table. If the gas type is not listed in the table, please
contact the manufacturer or supplier directly.
5.1 Replacing open burner nozzles
Remove the grate, the flame spreader, the burner and the drip pan;
Unscrew the screw that fixes the primary air sleeve and remove the sleeve;
Unscrew the nozzle using a 10-mm spanner and fit a suitable nozzle (refer to
Technical specifications table
).
5.5 Adjusting minimum output
If the appliance will be using liquid gases, remove the knobs, insert a screwdriver through the hole and completely screw down the
screw.
For other types of gas, you will need to adjust the screw as required until you obtain a stable and even flame. Proceed as follows:
Unscrew the screw;
Connect a liquid-filled pressure gauge (for example, a U-shaped pressure gauge, minimum scale division 0.1 mbar) or a digital
gauge;
Start up the appliance by following the instructions in the user’s manual;
Gas pressure at minimum burner output should match the pressure values under “Reduced pressure (mbar), minimum”.
5.6 Functional check
Start the appliance by following the
"Operating instructions"
;
Check for leaks;
Check for flame stability throughout the ON-OFF-ON control range;
Check the lighting process along the main burner and check that flames are even;
Check for proper operation of pilot flame;
Check that flue gases come out of the corresponding pipes regularly;
Check that there is a good inflow of fresh air.
6. Operating instructions
6.1 Before using the appliance
6.1.1 Preparing the appliance for use
Содержание RGR24X
Страница 2: ......