![ADEMCO AlarmNet 7835C Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/ademco/alarmnet-7835c/alarmnet-7835c_installation-instructions-manual_2850310032.webp)
– 32 –
6HFWLRQ7URXEOHVKRRWLQJ
Problem
Probable Cause
Solution
7835C not being received at the central
station. Message transmit successful;
yellow LED extinguishes, green LED
flashes 6 times.
Programming (subscriber number, central
station ID number, or city number.)
Verify and correct programming entry
with the 7720P. Refer to the Programming
section.
7835C not being received at the Central
station. Message transmit not successful.
Yellow LED is lit solid, red LED flashes 6
times.
Antenna location or installation.
Remove 7835C cover, check RSSI level
with a 7720P or the bar graph. Select a
better mounting location. Refer to
“Selecting a Suitable Installation Site”.
Ensure the antenna connector is not
damaged or obstructed. Ensure the
antenna is screwed down securely.
During installation, with cover removed,
using battery power and wall transformer
not plugged in, 7835C not being received
at the central station. Message transmit
not successful. Yellow LED is lit solid, red
LED flashes 6 times.
Battery is low.
Replace battery with a fully charged
battery or plug in the wall transformer.
Radio fault, solid red LED on the Radio
Status display.
Antenna location or installation.
Remove 7835C cover, check RSSI level
with a 7720P or the bar graph. Select a
better mounting location. Refer to
“Selecting a Suitable Installation Site”
section. Ensure the antenna connector is
not damaged or obstructed. Ensure the
antenna is screwed down securely.
Low Battery message sent with cover
installed and wall transformer installed,
during normal operation .
AC voltage supply
AC power loss, excessive AC wire run, or
incorrect transformer.
Environment.
If temperature exceeds -30°C to 60°C, this
will diminish battery capacity and or life.
Replace battery if required.
Tripping a zone or valid ECP message does
not generate a message pending display;
solid yellow LED
No connection ground.
Connect (–) trigger output (TB Pin 4) to
the panel ground.
Incorrect
trigger
input.
Verify type of input. Check P2 & P3
configuration.
Application of +4.5 to 12 volts (Non-
Inverted). Check programmed trigger
levels.
Absence of +4.5 to 12 volts (Inverted).
Check wiring.
Incorrect jumper settings. P2 & P3
See Setting the Jumper Options.
Radio will not initialize.
The 5 RSSI LEDs blink in unison during
initial power-up.
Data stored in EEPROM is corrupt.
Connect the 7720P and enter
programming mode. Skip all programming
questions and restore factory defaults as
described in Programming section.
Radio will not register.
Error in programmed features.
Verify programmed options. Change as
required.
No ECP communication between radio and
panel.
7720P programming tool has been left
plugged in.
Remove 7720P. This disables ECP
communications between the radio and the
panel.
Содержание AlarmNet 7835C
Страница 35: ...35 127 6...