– 15 –
Question 12
Pulse Z4 (Y/N)
Press “Y” if zone 4 is connected to a pulsed bell output. Question 12b will appear.
If you press “N,” the following appears.
Question 12a
Z4 Delay
(00-127)
Enter the reporting delay from 1-127 seconds for zone 4.
Enter “00” for no reporting delay.
Question 12b
Pulse Cnt?
(03 - 254)
If you is answered “Y” to “Pulse Z4,” the next question will be
“Pulse Cnt?” Input the number of pulses required to place the
zone in alarm.
Question 13
Pulse Z5(Y/N)
Press “Y” if zone 5 is connected to a pulsed bell output. Question 13b will appear.
If you press “N,” the following appears.
Question 13a
Z5 Delay
(00-127)
Enter the reporting delay from 1-127 seconds for zone 5.
Enter “00” for no reporting delay.
Question 13b
Pulse Cnt?
(03 - 254)
If you answered “Y” to “Pulse Z5,” the next question will be
“Pulse Cnt?” Input the number of pulses required to place the
zone in alarm.
Question 14
Pulse Z6 (Y/N)
Press “Y” if zone 6 is connected to a pulsed bell output. Question 14b will appear.
If you press “N,” the following appears.
Question 14a
Z6 Delay
(00-127)
Enter the reporting delay from 1-127 seconds for zone 6.
Enter “00” for no reporting delay.
Question 14b
Pulse Cnt?
(03 - 254)
If you answered “Y” to “Pulse Z6,” the next question will be
Pulse Cnt? Input the number of pulses required to place the
zone in alarm.
Inverted Zone Selection
You can program zones 1-6 for inverted input signals.
Question 15
Invert Z1 (Y/N)
Press “Y” to invert the input signal for zone 1. Press “N” for normal input signal.
Question 16
Invert Z2 (Y/N)
Press “Y” to invert the input signal for zone 2. Press “N” for normal input signal.
Question 17
Invert Z3 (Y/N)
Press “Y” to invert the input signal for zone 3. Press “N” for normal input signal.
Question 18
Invert Z4 (Y/N)
Press “Y” to invert the input signal for zone 4. Press “N” for normal input signal.
Question 19
Invert Z5 (Y/N)
Press “Y” to invert the input signal for zone 5. Press “N” for normal input signal.
Question 20
Invert Z6 (Y/N)
Press “Y” to invert the input signal for zone 6. Press “N” for normal input signal.