800-357-104-01, Revision 01
60
September 29, 2000
HMS-357 List 4 and List 5
HX
U
-3
5
7
Placing the Line Unit in Service at the HXU
The Wideband System 3190 interfaces internally to the 28 lines at the common DSX-1 point. Once a line has been
configured on the HLU, the DS1 interface at the HXU should be placed In-Service. Some alarm reporting will be
lost if the line is not placed In-Service.
The procedure to place a line unit in service varies by the type of multiplexer installed:
•
If you have an HXU-357—DS3, see
“Placing the Line Unit in Service Using an HXU-357 Multiplexer”
below.
•
If you have an HXU-358—DS3 (T1/E1), see
“Placing the Line Unit in Service Using an HXU-358
.
•
If you have an HXU-359—STS-1, see
“Placing the Line Unit in Service Using an HXU-359 Multiplexer” on
.
•
If you have an HXU-369—OC-3, see
“Placing the Line Unit in Service Using an HXU-369 Multiplexer” on
.
Placing the Line Unit in Service Using an HXU-357 Multiplexer
Step
Procedure
Installer Check
ü
ü
ü
ü
The following procedure assumes proper TAO login.
For proper login procedure, please refer to
“Using the Terminal Access Option” on
1
Access the HXU-357 Root Menu from the Shelf Status menu by pressing
and then the password.
H
2
Press
to select DS1 Equip/Unequip and then press
.
H
3
Enter the number of the channel line (or select all channel lines) and then press
.
H
4
Press
to select SET STATE TO (E)QUIPPED and then press
.
H
5
Press
to return to the Shelf Status menu.
H
6
Press
to select Configuration Management and then press
.
H
7
Press
to select Service Mode and then press
.
H
8
Press
to select DS1 Service Mode and then press
.
H
9
Enter the number of the channel line (or select all channel lines) and then press
.
H
10
Press
to select (I)N SERVICE and then press
.
H
11
Press
+
to return to the Configuration Management menu.
H
12
Proceed to
“Enabling Alarms for Systems Using an HXU-357 Multiplexer” on page 61
H
Installer Signature
?
?
?
?
Date
M
7
ENTER
ENTER
1
ENTER
ESC
1
ENTER
6
ENTER
2
ENTER
ENTER
1
ENTER
CTRL