800-357-104-01, Revision 01
Installing Multiplexers
HMS-357 List 4 and List 5
September 29, 2000
49
HXU
-35
9
Configuring DS1 Services through the Config Menu
Figure 31.
Setting Up DS1 Services Through the HXU-359
Step
Procedure
Installer Check
ü
ü
ü
ü
1
From the Config
submenu, choose Services, and then press
.
For more information on navigating through the menu system, refer to the procedures detailed in
“Setting Up Basic System Parameters through the Config Menu” on page 45
.
H
2
Select a DS1 service port, then press
.
The configuration bar at the bottom of the screen should show your selection.
H
3
If the selected DS1 port is configured as IS or OFF (Mode field):
•
Press the
key to select the Mode field.
•
Press the
to select OOS-A (default). Press
.
H
4
Choose the type of service (DS1).
H
Some units do not support both types of services.
5
Choose the type of line code [B8ZS (default) or AMI].
H
6
Choose the line buildout for the DS1 port [131 (default), 262, 393, 524, or 655 ft.].
H
Line load, line type, and line buildout must match the HCU card in use.
These settings should be set to the default values.
If an HCC-319 List 1 and List 2 Cut-through card is used, these settings should match
those of the external line connected to the port.
7
Select the Virtual Tributary Group (VTG) 1 through 7 and the Virtual Tributary Slot (VTS)
1 through 4. Only available combinations are presented for selection.
H
8
When finished configuring the port, reset the port to IS to place the line unit in service, then press
.
H
Main
Monitor
History
Config
Test
Inventory
Quit
Help
+--------------------------Services Configuration---------------------------+
|
#
Mode
Type
Code
LBO
Lpbk VTG VTS
|
|
01
OOS-A
DS1
B8ZS
131ft
NONE
0
0
|
|
02
OOS-A
DS1
B8ZS
131ft
NONE
1
2
|
|
03
OOS-A
DS1
B8ZS
131ft
NONE
1
3
|
|
04
OOS-A
DS1
B8ZS
131ft
NONE
1
4
|
|
05
OOS-A
DS1
B8ZS
131ft
NONE
2
1
|
|
06
OOS-A
DS1
B8ZS
131ft
NONE
2
2
|
|
07
OOS-A
DS1
B8ZS
131ft
NONE
2
3
|
|
08
OOS-A
DS1
B8ZS
131ft
NONE
2
4
|
|
09
OOS-A
DS1
B8ZS
131ft
NONE
3
1
|
|
10
OOS-A
DS1
B8ZS
131ft
NONE
3
2
|
|
11
OOS-A
DS1
B8ZS
131ft
NONE
3
3
|
|
12
OOS-A
DS1
B8ZS
131ft
NONE
3
4
|
|
13
OOS-A
DS1
B8ZS
131ft
NONE
4
1
|
|
14
OOS-A
DS1
B8ZS
131ft
NONE
4
2
|
|
(N)ext page (P)rev page (T)op (B)ottom (ENTER) edit srv. (ESC) quit
|
|
+----------------------------------------------+
|
|
|01
OOS-A
DS1
B8ZS
131ft
NONE
0
0|
|
|
+----------------------------------------------+
|
| (TAB) next field (Spacebar) next value (ENTER) activate (ESC) select srv. |
+---------------------------------------------------------------------------+
ID: ADC | Card 'B'
05/19/00 05:36:35
ALARMS: WARN
Config
ENTER
ENTER
TAB
SPACEBAR
ENTER
ENTER