800-357-104-01, Revision 01
Installing Multiplexers
HMS-357 List 4 and List 5
September 29, 2000
43
HXU-3
5
8
Configuring the DS3 Transport through the Config Menu
Figure 26.
Setting the DS3 Port Through the HXU-358
Step
Procedure
Installer Check
ü
ü
ü
ü
1
From the Config
menu, select
DS3 Port and then press
.
For more information on navigating through the menu system, refer to the procedures detailed in
“Setting Up Basic System Parameters Through the Config Menu” on page 39
H
2
Select
Service Mode, press the
to select MEM-ADMIN, then press
.
No configuration
changes can be made unless the Service Mode is configured as MEM-ADMIN.
H
3
If this is a dual multiplexer application, Protection Mode is automatically set to PROTECTED.
H
4
In most applications,
Operating Mode
should be set to M13.
H
5
Set
Line Buildout to 100FT (default) or 450FT.
H
In most applications Transmit Timing should be set to LOCAL.
6
Set the
BER Threshold
to E-03 (default), E-06, or E-09. (This sets the BER point at which an alarm
is declared and protection switching occurs.)
H
7
When you are finished configuring the DS3 Port, select Service Mode and change it to IN SERVICE.
H
8
Exit the Network Status screen by pressing
then
.
H
9
If you plan to install a fan assembly, proceed to
“Installing a Fan Assembly (Optional)” on page 54
;
“Installing a Line Unit (HLU)” on page 56
H
Installer Signature
?
?
?
?
Date
Main
Monitor
History
Config
Test
Inventory
Quit
Help
+-------------------+
| T1/E1 Ports
|
|
DS3 Port
|
+-----------------------------------------------------------+
| Service Mode(OUT OF SERVICE,IN SERVICE..):
IN SERVICE
|
| Protection Mode (PROTECTED,UNPROTECTED)
: UNPROTECTED
|
| DS3 Mode (M13,C-BIT)
: C-BIT
|
| Line Buildout (100FT,450FT)
: 100FT
|
| Transmit Timing (LOCAL,LOOP)
: LOCAL
|
| BER Threshold (E-03,E-06,E-09)
: E-03
|
+-----------------------------------------------------------+
Use <Spacebar> to cycle through option settings and <Enter> to activate
ID: 123456 | Card 'A'
01/18/00 14:12:21
ALARMS:
MAJ
ENTER
SPACEBAR
ENTER
ESC
ENTER